background image

Installation

 

1.  Turn off all power to fan. 
2.  If it is a new installation, cut and frame out a  

14” x 14” hole.  Prepare all wiring and fusing 
per specifications. 

3.  Remove old fan inside and out. 
4.  Carefully remove all old roof sealant.  

Surface must be clean and dry. 

5.  Check fit of new fan inside and out. 
 

--Hinge must face toward front of the RV. 

 

--Verify correct wiring size and length. 

 

--Check inside ceiling flange clearance. 

     

 

 

 

---To cut trim, see page 4 or call SHURflo. 

 

--Holes in roof exterior can be filled with   

 

  wood putty or sealant to ensure a better  

 

  seal later. 

6.  Apply 1” Butyl putty tape around mounting 

hole pattern on roof side of fan chassis. 

 

--Center the tape over the mounting holes. 

7.  Place unit on roof and check alignment 

inside and outside. 

 

--Hinge must be to the front of the RV. 

8.  Screw unit to roof with 28 screws. 

--

 Install screws slowly.  Torque = 10-15 in-lb.

 

 

--Screws from previous unit can be used. 

9.  Seal all edges and screws with silicone 

sealant, or use EPDM rubber roof sealant 
for rubber roofs. 

 

--Do not allow sealant to contact dome hinge 
or rain sensor. 

10. Check wire polarity and connect wires inside 

of coach.  Coach wires are either black (-) 
and red (+) or white (-) and black (+). 

 

--Fan red wire is positive (+).  Coach ( + ) 

 

   wire may be red or black. 

 

--Fan black wire is negative (--).  Coach ( -- )  

 

   wire may be black or white. 

 

--Polarity must be correct!  Check polarity  

 

   with voltmeter before attaching wires. 

11. Test hand crank by turning CW to open 

dome.   

 

--Crank must be in upper position for power  

 

  operation (if equipped). 

 

--Dome motor (if equipped) must be stopped  

 

  before moving hand crank in or out. 

12. Place lower trim in place and secure with 4 

screws provided.  To cut trim, see page 4. 

 

--Hand crank should be facing front 

13. Turn on main power to unit. 
14. Test unit. 

Operation 

Hand Dome Operation 

Use this knob to manually open or close the 
dome.  The dome can be stopped in any 
position.  If equipped with a motorized dome, 
pull the hand crank down to disengage the 
motor before turning by hand.  Push the hand 
crank up when finished to re-engage the dome 
motor.  

Dome must be fully closed when the 

RV is in motion. 
Fan On / Off & Speed Control 

Use this switch to turn the fan power on and off.  
This switch must be turned on to operate 
motorized dome and intake / exhaust direction, 
if equipped.  This switch also adjusts the fan 
speed to the desired setting.   

Fan Speed Control 

Turn the knob clockwise to increase fan speed 
and counterclockwise to decrease fan speed.  
Fan works best when a window or door is 
slightly opened to allow air to circulate in or out 
of the RV. 

Changing Fan Direction  
Intake / Exhaust Switch  

Press this switch to change fan direction to blow 
air out of the RV (Exhaust) or to bring outside 
air into the RV (Intake).  To ensure long product 
life, fan should be stopped before changing 
directions.  Fan works best with a window or 
door slightly open to allow air to circulate in or 
out of the RV. 

Power Dome Operation  
Dome Motor  

Press this switch to open or close the dome.  
The dome can be stopped in any position.  To 
conserve power, the fan will stop while the 
dome motor is running.  Automatic overload 
protection will stop the dome in case of an 
obstruction. 

 
  

 
 
 
 
 
 
 
 
 

911-725-D  

 

 

 

 

 

 

 

 

 

 

 

page 3 of 6 

 

Fan Cleaning

 

Turn off all power, and remove screen by 
unsnapping 4 fan clips.  Wipe fan with damp rag 
with mild detergent only.  Dry unit after wiping. 
Do not immerse fan in water.   
To replace screen, align clips and snap in place. 