9
Power, Audio, and RF Connections
1. Use the power adapter to connect the P3T to an AC power source.
2. Install 2 AA batteries in the bodypack receiver.
3. Attach the antenna to the BNC antenna con-
nector on the P3T rear panel.
4. Connect the mixer or audio source to the P3T au-
dio inputs using ¼ inch balanced cables.
Important:
When connecting to only one transmitter input, use the
LEFT/CH1
in-
put. Set the transmitter to
MONO
to hear audio on both channels of the receiver.
ௗ
MONO/STEREO-MX
LINE/AUX
LEFT/CH.1 IN
RIGHT/CH.2 IN
L - LOOP OUT - R
ANTENNA
POWER
PS23
MONO/STEREO-MX
LINE/AUX
LEFT/CH.1 IN
RIGHT/CH.2 IN
L - LOOP OUT - R
ANTENNA
POWER
Scanning for the Best Open Channel
Follow these steps to scan the RF environment and find the best available
frequency for operation:
1. Turn on the bodypack receiver and any potential sources
of interference, including wireless systems, computers, au-
dio equipment, cellular phones, LED panels, and other elec-
tronic devices that will be in use during a performance.
2. Make sure the P3T transmitter is
OFF
.
3. Position the receiver in the performance area and press
SCAN
to
survey the available channels within the current group setting.
If using several PSM300 systems or operating in a location with a high
volume of wireless devices, perform a group scan first, followed by a
channel scan:
Group Scan:
Press and hold the
SCAN
button on the receiver.
Channel Scan:
Press the
SCAN
button on the receiver.
power
group
channel
sync
PSM300 Transmitter P3T
(1-F)
(1-9)
input
Power = Off
Group
Channel
Scan
Creating a Wireless Connection Between
Receivers and Transmitters (Sync)
To pass audio from the transmitter to the receiver, both must be tuned to
the same frequency. The easiest way to configure the system is to use
the automatic sync feature. This transfers group and channel settings with
a press of a button. Based on your system configuration, use one of the
following processes to sync the components:
Align the IR windows to sync the receiver and transmitter
power
group
channel
sync
PSM300 Transmitter P3T
(1-F)
(1-9)
input
Pressing the
SYNC
button transfers group/channel data
Single Transmitter and Receiver
The following sync procedure should be used with a setup that consists of
a single transmitter and receiver, unless a group/channel setting has been
assigned prior to a performance.
power
group
(A-Y)
channel
(0-9)
sync
PSM300 Transmitter P3T
Sync from receiver to transmitter:
1. Perform a scan on the receiver (see "Scanning for
the Best Open Channel" for best practices).
2. Align the IR windows on the receiver and transmit-
ter. The windows should be 6-11 cm apart.
3. Press the
SYNC
button on the transmitter while the
blue RF LED on the receiver is flashing.
4. The Transmitter displays
SYNC
when the sync is suc-
cessful. The arrow between
Rx
(receiver) and
Tx
(transmitter) shows the direction of the sync.
Note: When the RF LED on the receiver is flashing after performing a scan, the re-
ceiver sends its frequency setting to the transmitter. After it stops flashing, press-
ing
SYNC
sends the frequency setting from the transmitter to the receiver.