Shure Incorporated
25/86
•
•
◦
◦
◦
◦
◦
◦
•
•
•
1.
2.
3.
1.
2.
3.
1.
2.
3.
4.
1.
2.
3.
Use balanced XLR cables for analog input/output.
Use Gigabit DHCP router to connect multiple access points in the same installation. Ensure it meets the following require
ments:
Gigabit ports
Provides Class 0 PoE with at least 6.5 W
Quality of Service (QoS) with 4 queues
Diffserv (DSCP) QoS with strict priority
If the router features Energy Efficient Ethernet (or Green Ethernet), ensure it is disabled from the ports dedicated for
the system
Recommended: A managed switch to provide detailed information about the operation of each network link (port
speed, error counters, bandwidth used, etc.)
Limiting cable runs to ≤100 meters between devices.
Use same firmware version for all devices in your system.
Ensure MXCW components and the computer are on the same network and set to the same subnet.
External Cover for Painting
The access point is supplied with an external cover that can be painted to match the decor around the installation. Snap onto
the front plate of the device after it has been painted.
Mounting Options
Wall or Ceiling:
Mark and drill pilot holes using the mounting bracket as a template.
Secure the mounting bracket to the surface using #8 (4 mm) screws (not included).
Connect the Ethernet cable to the access point using the cable route path and mount the access point to the bracket.
Electrical Box:
Pull the Ethernet cable through the electrical box.
Mount the bracket to the electrical box using #6-32 (3.5/16 mm) screws (not included).
Connect the Ethernet cable to the access point using the cable route path and mount the access point to the bracket.
Drywall:
Mark and drill pilot holes using the mounting bracket as a template.
Install drywall anchors.
Mount the bracket to the drywall anchors using #8 (4 mm) screws (not included).
Connect the Ethernet cable to the access point using the cable route path and mount the access point to the bracket.
Wood Paneling:
Mark and drill 3/32” (2 mm) holes using the mounting bracket as a template.
Mount the bracket to the wall using #8 (4 mm) screws (not included).
Connect the Ethernet cable to the access point using the cable route path and mount the access point to the bracket.