DCS 6000  Digital Conference System 

User Manual

 

 

consecutively. Pressing the down button when  the 
lowest  channel  number  is  displayed  will  cause  the 
channel  selection  to  wrap  around  to  the  highest 
available channel if the channel wrap parameter is 
set.  

Holding the  channel  up  or  down  button  depressed 
will  cause  the  channel  numbers  to  scroll  with  a 
system  defined  start-up  delay,  and  subsequent 
smaller  delay  between  each  change  in  channel 
position.  These  delays  are  set  using  system 
parameters. 

On power-up the channel number will be either the 
system  global  power  up  setting  or  a  locally  saved 
power-up channel or floor channel if a locally saved 
channel  number  is  outside  the  valid  channel 
numbers. 

Volume Control 

Volume  control  is  done  using  the  volume  up  and 
volume down buttons. The number of volume levels 
and the step size in dB between successive levels is 
globally  defined  using  system  parameters  – 
however  setting  the  volume  level  to  0  turns  the 
headphone/line output off.  

When  a  volume  button  is  depressed  the  channel 
display will be overridden with the current volume 
(this is indicated by the black dot in the upper left 
corner  of  the  display)  if  the  show  volume  global 
parameter is set. The display will continue to show 
the current volume level for a preset time interval 
before  returning  to  displaying  the  channel 
information – this time interval is also set globally 
using a system parameter. 

The  audio  can  be  attenuated  on  all  interpreted 
channels, when no interpretation is performed and 
floor is present on the channel. This feature can be 
used  when  the  channel  selector  is  used  in 
combination  with  an  analogue  microphone  system 
to  prevent  feed-back  from  the  channel  selector  to 
the  microphone  if  the  delegate  is  speaking  and 
listening to the same channel. The attenuation in dB 
is set globally – however  enabling or disabling this 
feature  can  be  set  individually  on  the  channel 
selectors. 

Storing local setup in FLASH 

If enabled by the central unit the channel selectors 
may  store  the  following  local  parameters  in  flash 
memory thus overriding the global system settings 

 

start-up volume level  

 

startup channel number  

 

attenuate floor audio on interpreted channel  

To change the local setup in flash memory this must 
be globally enabled from the CU. 

To set a new startup volume level use the volume 
up  or  down  button  to  change  to  the  wanted 
volume level and then depress both channel up 
and  channel  down  buttons.  After  a  short  time 
period the display will show 

F1 – 

if the buttons 

are released while the display is showing 

F1

 the 

display will change to 

FP

 to indicate that the new 

value is now programmed into flash memory. To 
clear  the  locally  saved  volume  level  position 
depress  both  channel  up  and  channel  down 
buttons until the display shows 

C1

 then release 

the buttons – the display will then change to 

FC

 

to indicate that the flash is cleared of this setting. 

To  set  a  new  start  up  channel  position  use  the 
channel  up  or  down  button  to  change  to  the 
wanted channel position and then depress both 
volume  up  and  volume  down  buttons.  After  a 
short  time  period  the  display  will  show 

F2

  –  if  

the  buttons  are  released  while  the  display  is 
showing 

F2

  the  display  will  change  to 

FP

  to 

indicate that the new value is now programmed 
into  flash  memory.  To  clear  the  locally  saved 
start up channel position depress both volume up 
and  down  buttons  until  the  display  shows 

C2

 

then release the buttons – the display will then 
change to 

FC

 to indicate that the flash is cleared 

of this setting. 

To  activate  the  attenuate  floor  audio  on 
interpreted  channel  functionality  of  a  unit 
depress  the  volume  down  and  channel  up 
buttons. After a short time period the display will 
show 

F4

 – if the buttons are released while the 

display is showing 

F4

 the display will change to 

FP

 indicating that the activation is now saved to 

flash. To deactivate the attenuate floor audio on 
interpreted  channel  functionality  of  a  unit 
depress  the  volume  down  and  channel  up 
buttons until the display shows 

C4

 then release 

the buttons – the display will then change to 

FC

 

to indicate that the activation is now cleared from 
flash. 

Startup / Error conditions 

The  following  conditions  in  addition  to  the 
channel number are displayed: 

 

E0-E4, network error 

 

E5, network error or firmware mismatch 

 

E9, reset 

The channel selector will always show E1 shortly 
when powering up, then the display will change 
to show the channel number.  

If  any  of  the  “E0-E5”  messages  is  shown 
constantly,  please  check  your  cables  and  verify 
that  the  terminator  plug  is  inserted  in  the  last 
unit in the chain.

 

Содержание CS 6340 F

Страница 1: ...2015 Shure Incorporated User Manual CS 6340F rev A docx Conferencing and Discussion Systems CS 6340 F Channel Selectors USER GUIDE...

Страница 2: ...CS 6000 Conference System 5 The DCS 6000 system 5 System components 6 Central equipment etc 6 Interpreter equipment 6 Conference units and Ch selectors 6 Accessories 6 Operating instructions 7 CS 6340...

Страница 3: ...st conforme la norme NMB 003 du Canada Authorized under the verification provision of FCC Part 15B Please follow your regional recycling scheme for batteries packaging and electronic waste Information...

Страница 4: ...e organic solvents such as thinners or abrasive cleaners since these will damage the cabinet Repacking Save the original shipping cardboard box and packing material they will become handy if you ever...

Страница 5: ...nel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit w...

Страница 6: ...t portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F Conference Un...

Страница 7: ...uttons are used for changing the channel setting or changing the volume setting The buttons are also used for saving the settings or other control purposes Connectors Headphone Connector mini jack A m...

Страница 8: ...annel To change the local setup in flash memory this must be globally enabled from the CU To set a new startup volume level use the volume up or down button to change to the wanted volume level and th...

Страница 9: ...e length in one chain when not using repeaters is 200 m Maximum cable length in one chain when using repeaters is 650 m If the last unit in a chain is a CS 6032F the unit must have a DCS LAN Network T...

Страница 10: ...ing on the current system setting Volume step size Show volume Volume channel step initial successive delay Connectors DCS LAN network 2 pieces RJ45 8 pin Analog outputs connector front 3 5 mm mini ja...

Страница 11: ...GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6 Pair 1 Pin 4 5 Pair 4 Pin 7 8 The...

Страница 12: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Отзывы: