background image

Shure Incorporated

8/23

Shure Rechargeable Batteries

Shure lithium-ion batteries offer a rechargeable option for powering the transmitters. Batteries quickly charge to 50% capacity 

in one hour and reach full charge within three hours.

Single chargers and multiple bay chargers are available to recharge the Shure batteries.

Caution: 

Only charge Shure rechargeable batteries with a Shure battery charger.

Checking Battery Info

When using a Shure rechargeable battery, the receiver and transmitter home screens display the number of hours and minutes 

remaining.

Detailed information for the battery is displayed Battery menu of the transmitter: 

Utilities

 > 

Battery

Battery: The chemistry type of for the installed battery (Shure, Alkaline, Lithium, NiMH)

Bars: Indicates the number of bars displayed

Time: Battery runtime

Charge: Percentage of charge capacity

Health: Percentage of current battery health

Cycle Count:

 Total of the number of charging cycles for the installed battery

Temperature: Battery temperature reported in Celsius and Fahrenheit

Important Tips for Care and Storage of Shure Rechargeable Batteries

Proper care and storage of Shure batteries results in reliable performance and ensures a long lifetime.

Always store batteries and transmitters at room temperature

Ideally, batteries should be charged to approximately 40% of capacity for long-term storage

Periodically clean the battery contacts with alcohol to maintain ideal contact

During storage, check batteries every 6 months and recharge to 40% of capacity as needed

For additional rechargeable battery information, visit www.shure.com.

Содержание AXIENT DIGITAL ADX2FD

Страница 1: ...ADX2FD Handheld Transmitter User guide for the Shure ADX2FD Frequency Diversity handheld transmitter Version 11 0 2020 K...

Страница 2: ...tallation 9 ADX2FD SB920 Battery Runtime 9 Installing the Battery Contact Cover 9 Menu Parameters 9 Tips for Editing Menu Parameters 10 Menu Map 10 Menu Parameter Descriptions 10 Radio Menu 10 Audio M...

Страница 3: ...from small children Do not use abnormal batteries Pack the battery securely for transport Note Use only with the included power supply or a Shure approved equivalent ADX2FD Handheld Transmitter ADX se...

Страница 4: ...gged metal construction Menu and power lockout Power Shure SB920 rechargeable batteries offer precision metering and zero memory effect External charging contacts for docked charging Battery Runtime w...

Страница 5: ...A RPW118 BETA 87A RPW120 BETA 87C RPW122 VP68 RPW124 KSM9 Nickel RPW188 KSM9HS Nickel RPW190 KSM9 Black RPW184 KSM9HS Black RPW186 ADX2FD Transmitter Overview Microphone Cartridge See Optional Accesso...

Страница 6: ...ange values X Acts as a back button to return to previous menus or parameters without confirming a value change O Enters menu screens and confirms parameter changes Use to scroll through menu screens...

Страница 7: ...is attempted to a locked control power or menu ShowLink signal strength displays 0 to 5 bars STD Standard Transmission Mode HD High Density Transmission Mode RF Mute Engaged Displayed when RF output...

Страница 8: ...installed battery Shure Alkaline Lithium NiMH Bars Indicates the number of bars displayed Time Battery runtime Charge Percentage of charge capacity Health Percentage of current battery health Cycle Co...

Страница 9: ...he bottom of the battery ADX2FD SB920 Battery Runtime Note Higher RF power levels decrease battery runtime Battery runtime varies with battery age and environmental conditions Signal Carrier Mode Freq...

Страница 10: ...ers To access the menu options from the home screen press O Use the arrow buttons to access additional menus and para meters A menu parameter will blink when editing is enabled To increase decrease or...

Страница 11: ...ttery runtime Output On RF signal is active Mute RF signal is inactive Audio Menu Offset Adjust Offset level to balance mic levels when using two transmitters or when assigning multiple transmitters t...

Страница 12: ...r of charging cycles for the installed battery Temperature Battery temperature reported in Celsius and Fahrenheit Talk Sw Press ENTER to add control from a talk switch Press the button on the talk swi...

Страница 13: ...a transmitter perform an IR sync with the desired receiver channel Setting the Frequency Manually The transmitter can be manually tuned to a specific frequency group or channel Navigate to the Radio...

Страница 14: ...ke changes To exit the Safe Start menu cycle the power or momentarily remove the battery Previous settings for locks and RF will be retained when the transmitter is powered on in Safe Start Operating...

Страница 15: ...di tional indicator of an overload Reduce the input signal or enable the input pad to remove the overload condition Tip To enable the input pad navigate to Audio Pad and select 12 dB Tone Generator Th...

Страница 16: ...bar is displayed If the transmitter is beyond the coverage range ShowLink control will not be possible However the audio signal will not be af fected or interrupted as long as the transmitter is withi...

Страница 17: ...re download which can take 50 seconds or longer The red alignment LED will turn on when the alignment is correct Press ENTER on the receiver to begin the download to the transmitter The receiver will...

Страница 18: ...de 350 kHz High Density Mode 125 kHz Modulation Type Shure Axient Digital Proprietary Power See Frequency Range and Output Power table varies by region Single Carrier Mode 2 mW 10 mW 50 mW Frequency D...

Страница 19: ...10 20 K53 606 to 698 2 10 50 2 10 20 K55 606 to 694 2 10 50 2 10 20 K56 606 to 714 2 10 50 2 10 20 K57 606 to 790 2 10 50 2 10 20 K58 622 to 698 2 10 50 2 10 20 L54 630 to 787 2 10 50 2 10 20 L60 630...

Страница 20: ...quipment may be capable of operating on some frequencies not authorized in your region See Licensing Information G56 470 636 MHz Country Code Code de Pays Codice di paese C digo de pa s L nder K rzel...

Страница 21: ...d must comply with all the conditions of that licence including operating frequencies Before 31 December 2014 this device will comply if it is operated in the 520 820 MHz frequency band WARNING After...

Страница 22: ...has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interf...

Страница 23: ...t D veloppement conomique Canada This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Develop ment Canada s licence exempt RSS s Operation is s...