Manual of SR258 intelligent controller
7
Put the cover on the housing. Attach with the fastening screw.
3.2 Wiring connection
According to the way of installation, wire can be connected from hole A on the bottom plate
or from hole B, using a suitable tool (like knife) to cut the plastic of A.
Note:
wires must be fastened by fixing clamps on the position C.
3.3 Terminal connection
3.3.1 Electri cal heating 1500W version terminal ports and wring
Note:
before opening the housing! Always disconnect the controller from power
supply and obey the loc al electrical supply regulation.
Input ports
T1: PT1000 temperature sensor, for measuring the temperature of collector and thermal
energy calculation.
T2 ~T5: NTC10K, B=3950 temperature sensor, for measuring temperat ure of tank and
pipe.
PWM1: Signal ports for high efficiency pump, detailed connect ion see below
FRT: For rotary vane type electronic flowmet er.