35
TROUBLESHOOTING GUIDE
Problem
Probable Cause
Remedy
Gun will not ignite
Safety and/or trigger are
not fully depressed.
Depress the safety first, and
then pull the trigger to ignite.
Trigger is pulled to quickly.
Squeeze the trigger slowly to
ensure the propane has entered
the combustor before firing.
Propane tank pressure
too low.
Check the regulator to make
sure the Gauge is reading a
minimum of 1.4 bar.
Propane tank valve is not
turned on.
Turn on tank valve and check
the regulator gauge for proper
pressure setting.
Defective igniter
With propane turned off and gas
purged from the hose, check for
spark in the combustor.
Trigger is pulled too quickly.
Содержание MZ Metric CE
Страница 1: ...Operating Field Maintenance and Parts Manual Model MZ Metric CE ...
Страница 25: ...23 OPERATING OVERVIEW ...
Страница 27: ...25 MZ PART NUMBER AND DESCRIPTION ...
Страница 40: ...SHRINKFAST 460 Sunapee Street Newport NH 03773 1488 603 863 7719 or email at info shrinkfasttools com ...