Safety lock located at TEST MODE.
Pressuriser for about 13s, pressure value failed to reach 100%, system will report E1.
Possible fault: No fuel, pump failure, pipeline problem etc.
Pipeline can't release pressure leads to pressure relief error.
Possible fault: pressure release valve failure, pipeline problem or control system problem etc.
Motor fault Possible fault: swiveling nozzle stuck, motor failure etc.
Battery voltage
>
15V or
<
10V for continuous 5s, machine stops running.
Possible fault: the battery is low.
if the machine slant over 45° , it stops running
,
system will report E6.
Alert Message
E0 System Lock
E1 Pressure Err
E2 P Relief Err
E3 Motor Err
When Ext Ignite is ON, device will pressuriser automatically when switch safety lock to USER
MODE; decompression when switch to TEST MODE. 9V-60V fireworks ignitor signal will
trigger related firing sequences.
E4 Ext Ignition
E5 Voltage Err
E6 Tip Err
DMX signal blocked in factory mode.
E7 Factory Mode
5. Alert Message
Press “MENU” to switch through setup menu.
Menu
Range
Explanation
Set DMX Address
1~512
DMX address setup
Set Rotation Mode
Angle Limit
Note: Angle limit activate
under half cycle mode
Full Cycle Mode
(
360
)
/
Half Cycle Mode
(
180
)
MIN: NO.1-NO.15
MAX: NO.1-NO.15
Restrict nozzle rotate angles: Set by "+" and
"-" , and confirm by "ENTER"
Switch Cycle Mode
6. Interface setup