background image

Responsibility Excellence Innovation

Interface

Main Interface:

Error informations display table

Setting interface

Page-4/8

First line   : Display DMX address is “1”.
Second line  : Display the present inner core temperature and the temperature progress bar; 
displays remianing time is 7 minutes and 24 seconds. 

Press “MENU” to enter the Setting interface, press the “MENU” button to enter different 
options until you return to the main interface.

Options

Set DMX

Address

Wireless

Control

Manual

Fountain

Auto Clear

Delay

Range

1-512

ON/OFF

ON/OFF

0.1-0.9s

Instructions

Set the DMX address. machine become a wireless host and

can send out DMX signal when it’s address is “1++”.

Wireless function switch. you can match codeWhen shows “ON”

Manual fountain switch , for testing purposes only.

Automatic clear material settings.

Error Informations

Introductions

E0 System IC

System error.

E2 Temp. Sensor

Temperature sensor was damaged.

E3 P Temp. Over

Chassis temperature too high lead to shut down.

E4 Time Remain

Insufficient granules or remaining time, please swiping time card.

E5 K Temp. Over

Inner core temperature too high lead to shut down

E6 Heat Fail

Heating failed.

E7 Tip Over

Dumping alarm when machine is tilted at less than 45 degrees. 

machine stop working when tilt alarm starts.

Содержание Sparkular mini BT06

Страница 1: ...User Manual Sparkular mini V1 0 Liuyang Xiaowen Electronic Technologies Co Ltd ...

Страница 2: ... Keep audience and flammable material at a minimum distance of 3m from SPARKULAR mini Make sure sparks shoot out from Sparkular mini can NOT touch any objects Clear material for Sparkular mini is necessary both before the show and after the show to clear the Composite Ti remains in the pipe Check whether there are Composite Ti aggregate in the nozzle after each show if any please clean it up or it...

Страница 3: ...on More secure Sophisticated design light weighted and portable Sparkular Mini Model No BT06 Parameter Size Weight Input Parameter Working Power Working Temperature Casing Fountain Height Interface 4 5kg 200 240VAC 50 60Hz 300w 10 50 ABS 2 0m 3 5m Depend on different type of composite Ti Double DMX input interfaces double AC power interfaces 168 180 228mm ...

Страница 4: ... diode display area Control button area Radio frequency identification area READY After turn on machine it will automatically preheat around 5 minutes when the READY green light turns from flashing into long on indicates that the machine is ready to work DMX Flashing shows that DMX signal is connected otherwise is without signal FAULT When any malfunction the light turn on HEAT When the machine is...

Страница 5: ... OFF 0 1 0 9s Instructions Set the DMX address machine become a wireless host and can send out DMX signal when it s address is 1 Wireless function switch you can match codeWhen shows ON Manual fountain switch for testing purposes only Automatic clear material settings Error Informations Introductions E0 System IC System error E2 Temp Sensor Temperature sensor was damaged E3 P Temp Over Chassis tem...

Страница 6: ...hould be over 1 5 square If the remote control cannot work please check whether wireless function was turn on Press MENU to switch to wireless control setting menu is set to ON press ENTER This interface can also be mactching code with remote controller Sparkular mini can controlled by both DMX and remote controller when there are DMX signal input wireless remote controller will not work When usin...

Страница 7: ... it is suggest to stay as close to machine as possible when use remote controller and machines cannot use metal shielding In occasion of strong interference using the wireless host can avoid interference ensure stable control Set the first unit of Sparkular mini DMX address into 1 this machine address is 1 but it can also output DMX signal and turns into wireless host Sparkular mini Use communicat...

Страница 8: ... mode Page 7 8 When using the DMX controller the system takes 2 channels The First channel Functions 0 15 Fountain OFF 16 255s Fountain ON The second channel Functions 60 80 Clear Material 20 40 Emergency Stop 0 10 240 255 Pre heat OFF Pre heat ON ...

Страница 9: ...used by human factors in warrantyperiod Please don t repair machine without factory permission 1 Damage caused by improper transportation using management and maintenance or damage caused by human factors 2 Disassemble modified or maintenance products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use F...

Страница 10: ...ogies Co Ltd Responsibility Excellence Innovation Add Building B1 Changsha E center No 18 Xiangtai Road Economic Technology Development Zone Hunan China Tel 86 731 83833068 Fax 86 731 83833069 Web www showven com E mail info showven com ...