background image

Radio frequency identification area

Main interface

Error informations display table

Setting interface

Interface

Composite Ti with RFID card, swiping cards used to identify parameters

and types of granules.

Please note that granules RFID card can increase the single machine 

specific working time. The card is disposable,one card can only use one time.

First line

Display DMX address is “1”.

Second line: Display the present inner core temperature and the temperature progress bar; displays 

remianing time is 7 minutes and 24 seconds. 

Press “MENU” to enter the Setting interface, press the “MENU” button to enter different options until 

you return to the main interface.

Options

Range

Explanation

Set DMX Address

Wireless Control

Manual Fountain

1-512

ON/OFF

ON/OFF

Set the DMX address,machine become a wireless host and can 

send out DMX signal when its address is “1++”.

Wireless function switch,you can match code when shows “ON”

Manual fountain switch , for testing purpose only.

Error Informations

Explanation

E0 System IC
E2 Temp. Sensor

E3 P Temp. Over
E4 Time Remain
E5 K Temp. Over
E6 Heat Fail

System error.

Temperature sensor was damaged.
Chassis temperature is too high to shut down.
Insufficient granules or remaining time, please swiping time card.
Inner core temperature is too high to shut down
Heating failed.

Advanced menu

 

Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key to enter different 

options, press MENU till 3 seconds to return to the main interface.

Options

Explanation

Range

Set Temperature
Auto Heat
Density

Mode Selection

Default Parameter

500-610

ON/OFF

70-100

Factory Mode/User Mode

Setup inner Core temperature.
Auto preheat function switch after turning on machine.
Adjust the sparks density.
Factory Mode is factory debugging mode, 

User Mode is using mode.

Press “ENTER” to restore all parameters to the

factory settings.

3

Содержание SPARKULAR FALL

Страница 1: ...V1 1 SPARKULAR FALL USER MANUAL Showven Technologies Co Ltd ...

Страница 2: ...l Accidentally Burning of Composite Ti can only use sands to extinguish Composite Ti should keep away from moisture and stored in a dry sealed environment Keep audience and flammable material at a minimum distance of 3m from SPARKULAR FALL and it s drop sparks Make sure sparks shoot out from Sparkular FALL can NOT touch any objects Ensure that children animals and unauthorized persons don t have a...

Страница 3: ...y to work DMX Flashing shows that DMX signal is connected otherwise is without signal FAULT When any malfunction the light turns on HEAT When the machine is heating signal light turns on Bottom Indication Light Off Sparking or Not in preheating Quick Flashing Preheating Long on Preheated Slow Flashing Error warning Control button area MENU Short press to switch interface press for 3 seconds can sw...

Страница 4: ...DMX signal when its address is 1 Wireless function switch you can match code when shows ON Manual fountain switch for testing purpose only Error Informations Explanation E0 System IC E2 Temp Sensor E3 P Temp Over E4 Time Remain E5 K Temp Over E6 Heat Fail System error Temperature sensor was damaged Chassis temperature is too high to shut down Insufficient granules or remaining time please swiping ...

Страница 5: ...ase check whether wireless function was turn on Press MENU to switch to wireless control setting menu is set to ON press ENTER In this interface you can also match code with remote controller Sparkular Fall can controlled by both DMX and remote controller when there are DMX signal input wireless remote controller will not work When using remote controller you need to pull out the antenna After pre...

Страница 6: ...he first unit of Sparkular Fall s DMX address into 1 this machine address is 1 but it can also output DMX signal and turns into wireless host Sparkular Fall Use communication cables to connect all the Sparkular Fall the host Sparkular Fall will receive the signal from remote controller and trans fer to all other Sparkular Fall via communication cables to realize stable signal transmission Attentio...

Страница 7: ...s NOT included in warranty service 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage not included in warranty range we can provide pai...

Страница 8: ...hnologies Co Ltd Add Building B1 Changsha E Center No 18 Xiangtai Road Liuyang Economic Development Zone Changsha City 410300 Hunan Province P R China Tel 86 731 83833068 Web www showven cn E mail info showven cn ...

Отзывы: