background image

2.Host Controller

1) Description 

2) Host Controller Introduction – Standard or Pro Version

1. ZK6200/ZK6300 Host Controller is an intelligent system specially designed for the multi-effects and remote control of 

Sparkular series machine, so as to create the simulation and demonstration of sparks effects. The audio trigger and timing 

code trigger can be used to control the synchronous with music. LAN ports can be used to extend the communication 

among multi host controllers.  

a) Standard DMX512 signal output

b) Support 18 units Sparkular at the same time (ZK6300 54 units).

c) Five standard dynamic effect modes: Synchronization, Center to Ends, Ends to Center, Left to right, Right To Left,       

   Special Effects and one user-definable special effect mode (together with SPARKULAREdit 200 software from  

   

   SHOWVEN), supports 8 files and each file supports 36000 lines at maximum (special effects last for 30 minutes)

d) There are multiple optional trigger sources. Hand, Music or Midi Inputs.

e) Support simulation function and LED display.

f) Monitoring function: Host controller with RDMX function, can feedback status information such as Temp., error  

 

   message etc. of each machine.  

g) Emergency stop function:  Pause or Stop Button.

Model 

    ZK6200

Dimension 

 

 

 

390 x 300 x 110mm

Weight 

    3.5kg

Input 

    AC 

110V-240V, 

50/60Hz

Work 

Power 

   15W

Work 

Temp. 

   -10

~50

Ports 

    2 

CAN 

communication 

ports,

     1 

USB 

port,

     2 

media 

ports(trigger 

by 

music),

     2 

MIDI 

ports(trigger 

by 

music),

     2 

DMX512 

output 

ports, 

Ethernet.

Support max. 

 

 

 

200m communication cable

Battery 

    3350mAH

Lifetime 

    >3 

years

8

Содержание SPARKULAR BT01

Страница 1: ...Showven Technologies Co Ltd V1 1 SPARKULAR USER MANUAL ...

Страница 2: ... FROM ELECTRIC SHOCK UNDER NO CIRCUMSTANCES ARE YOU TO ATTEMPT TO OPEN THE MACHINE AND CONTROLLER OR ATTMPT TO REMOVE OR ADJUST ANY COMPONENTS FITTED WITHIN THE MACHINE AND CONTROLLER ONLY FULL TRAINED SERVICE ENGINEERS ARE QUALIFIED TO OPEN THE MACHINE AND CONTROLLER Caution Against Liquids WARNING USE CAUTION SO THAT ANY LIQUIDS DO NOT WET THE MACHINE KEEP THE MACHINE AND CONTROLLER DRYAND NOT U...

Страница 3: ...R THERE ARE ACCUMULATED GRANULES PLEASE CLEAN OUT EXCESS BY INVERTING THE UNIT TO CLEAN OUT PORT EACH TIME BEFORE AND AFTER THE SHOW PLEASE RUNNING CLEAR MATERIAL ON HOST CONTROLLER OR DMX CONSOLE BEFORE DELIVERY THE MACHINE OR NOT USE THE MACHINE IN A LONG TIME PLEASE POURING THE HC8200 OUT FROM HOPPER AND STORE THE REMAINING HC8200 IN A DRY SEALED BOTTLE FOR NEXT TIME USE Power Supply Requiremen...

Страница 4: ...e for other DMX console Below descriptions will help to learn the operation and function of SPARKULAR systems 1 Description 2 Instructions A Safe no gunpowder no smoke and pyro smell B Up to 10 20min effects time after fill up C Standard DMX 512 control D Adjustable height from 1 5 5m E Easy set up and tear down F Indoor outdoor usage G Flexible for rehearsal H Environmental friendly I Patented an...

Страница 5: ... Communication Signal Input DMX OUT DMX Communication Signal Output e Radio Frequency Identification Area RFID card comes together with HC8200 it is a safety design allow machines to identify the parameter and types of consumable it adding to the hopper of machine It is obligatory to swiping the card before adding the consumable HC8200 to the hopper of machine Note Please note that the card enable...

Страница 6: ...stops due to over temperature of the inner core E6 Heating Failure Heating fail problem on heating PCB of mainboard E7 Tip Over Tilt sensor activated when machine slant more than 45 degree Press MENU switch through setup menu DMX address setup for SPARKULAR Option Set DMX Address Fountain Height Manual Heat Range 1 512 Explanation Set DMX Address Manual Fountain DMX Address 1 10 On Off On Off 10 g...

Страница 7: ...y Mode User Mode On Off 220 110Vac Setup SPARKULAR inner core temperature Wireless On Off for wireless version only LCD Backlight On Off Adjusts the sparks density of Height gear 1 Adjusts the sparks density of Height gear 2 Adjusts the sparks density of Height gear 3 Adjusts the sparks density of Height gear 4 Adjusts the sparks density of Height gear 5 Adjusts the sparks density of Height gear 6...

Страница 8: ...183 184 207 208 231 232 255 Second Channel 60 80 20 40 0 10 240 255 Fountain Off Fountain Height 1 Fountain Height 2 Fountain Height 3 Fountain Height 4 Fountain Height 5 Fountain Height 6 Fountain Height 7 Fountain Height 8 Fountain Height 9 Fountain Height 10 Function Clear Material EMERGENCY STOP Pre heat Off Pre heat On 7 ...

Страница 9: ...to right Right To Left Special Effects and one user definable special effect mode together with SPARKULAREdit 200 software from SHOWVEN supports 8 files and each file supports 36000 lines at maximum special effects last for 30 minutes d There are multiple optional trigger sources Hand Music or Midi Inputs e Support simulation function and LED display f Monitoring function Host controller with RDMX...

Страница 10: ... link the remote control feature Download SparkularEdit200 software Port No 1 to No 18 is Sparkular number Firing Stop of each unit of Sparkular by press related key of 1 to18 The Sparkular can be operated after the Pre Heat warm up for 5 minutes The indicator light will switch from flash green to always on when heating up was ready When firing is activated the indicator light will change to Red P...

Страница 11: ... operating time can be put backward Clear Material Clear material of SPARKULAR before and after each show to clean the remaining consumable in the heating chamber avoid blocking of the SPARKULAR Pre heat Press Pre heat to heating up the SPARKULAR It takes around 5min For long time not use the machine suggest to turn off the Pre heat function and allow SPARKULAR to return to normal temperature Firi...

Страница 12: ... there are error information it will also show in this area b Error Information Option FILE NO FIRING HEIGHT FIRING DURATION TRIGER DELAY Scope REPEAT PERIOD REPEAT COUNTS 1 8 1 10 0 1 30 0s 0 1 30 0s 0 1 50 0s 1 5 File number Fountain Height gear button can change height10 directly Duration of the Fountain Trigger delay between two machines Time to start of next sequence period Repeated times Ill...

Страница 13: ...C No matter which mode the Trigger Source selected the operation of the device can be started and stopped synchronous ly by SparkularEdit200 connected computer 5 The Use of the Special Effect Mode Option SPARKULAR Start No SPARKULAR End No Trigger Source Audio Level Range Audio Filter Delay Mode Selection 1 18 1 18 HAND AUDIO MIDI 1 2 3 4 10 100ms User Mode Factory Mode Select range Select range T...

Страница 14: ... Power Link Cable Connection between Sparkular DMX Communication Cable Power Supply Cable Sparkular Power Link Cable Sparkular Sparkular 3 System Configuration and Connection 1 System Configuration Sparkular Standard DMX Communication Cable 2 1 4 3 5 6 Host Controller AC Input 3PIN Power Supply Cable Standard DMX Communication Cable Host Controller ZK6200 Sparkular 13 ...

Страница 15: ...lid Open the hopper lid Funnel and Nozzel plug not standard configuration can order from SHOWVEN Filling the hopper Close the lid of hopper 4 System Prepare and Start 1 Fill the Sparkular consumable HC8200 to Sparkular Model Effect height HC8200 SMALL 1 5 3m HC8200 MEDIUM 1 5 3 5m HC8200 LARGE 2 5m a Open HC8200 pouch b Fill SPARKULAR hopper SMALL MEDIUM LARGE d Communication Cable Connection betw...

Страница 16: ...HC8200 Read the card as show below SPARKULAR shows time remain if read successfully SPARKULAR report E4 when remaining time is less than 10 minutes 6 Firing Activate programming effects by press FIRING on the host controller 5 Activate Sparkular machine After show please power off Sparkular and host controller Allow SPARKULAR to cool down before packing Never touch the nozzle of SPARKULAR DANGER O...

Страница 17: ...ase running Clear Material both before and after each show Before delivery or not use machine in a long time please pouring the HC8200 out of hopper and store the remaining HC8200 in a dry sealed bottle for next time use 8 Clear Material Tools To empty Granular material 16 ...

Страница 18: ...ice for machines which with hardware malfunction except for the instrument damage caused by human factors in warranty period Please don t repair machine without factory permission 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reasons light...

Страница 19: ......

Страница 20: ...hnologies Co Ltd Add Building B1 Changsha E Center No 18 Xiangtai Road Liuyang Economic Development Zone Changsha City 410300 Hunan Province P R China Tel 86 731 83833068 Web www showven cn E mail info showven cn ...

Отзывы: