1. Please read above safety information carefully before operating the machine.
2. Fill the fluid tank with SHOWVEN original fog fluid, pay attention to the maximum fill level.
3. Connect the machine to suitable rated power supply, due to the work power is relatively high,
please ensure power supply meets the requirement.
4. Turn on the machine, it heat up automatically, and shows “warm up” on LCD screen.
5. Once the machine has reached operating temperature, “Warm up” disappear and temperature
reached at around 100%, pressure at around 100%. Now the machine is ready for operation.
6. After each firing, wait a few seconds to start the next firing, allow the pressure and temperature
are stable.
Example of “TIMER” setting function in the menu:
①
“set interval 10s”
②
“set duration 2s”
SONICBOOM will repeat: firing 2s, interval of 10s, firing 2s, interval 10s…
Press “VOLUME” button under main interface, SONICBOOM activated and start to generate smoke,
and press “STOP” to stop the machine.
LED color setting:
0: LED OFF
1: RED
2: GREEN
3: BLUE
4: PINK
5: PURPLE
6: ORANGE
7: YELLOW
8: SKY BLUE
9: WHITE
Above setting disabled when use DMX console, LED color determined by setting on console.
When choose 1 channel mode, LED color determined by single channel, DMX value and related color
as below:
Press “MENU” switch through setup menu.
b) Setting Menu
c) Advanced Interface
Color
DMX value
SMOKE OFF
0-40
RED
41-60
GREEN
61-80
BLUE
81-100
PINK
101-120
PURPLE
121-140
ORANGE
141-160
YELLOW
161-180
SKY BLUE
181-200
WHITE
201-220
Random
221-235
LED OFF
236-255
Items
DMX 512 Address
Power Regulation
Color Optional
SonicBoom Mode
Single Channel
Explanation
Set DMX address
Setting working power for the
machine
LED color set when manual firing
Setting working mode
Single channel mode set
Range
1~506
Standard/Half Power
0~10
Regular mode/Sonicboom mode
ON/OFF
Press “MENU” for 3s, enter advanced setting interface
Item
Manual Evacuate
Interval Set
Duration Set
Wireless Remote
Language
Explanation
Manual Evacuate when pressure always insufficient
Interval time
Smoke output duration
Wireless ON/OFF switch
Language switch
Value
ON/OFF
0-200
0-8
ON/OFF
Chinese/English
Manual Pump
For maintenance
ON/OFF
4
Содержание Sonicboom Smokejet
Страница 1: ...Showven Technologies Co Ltd V1 0 ...