There are 16 ignition position on our slave.
Below 3 setting example will help to understand the Address start, Address end, Point start and
Point end.
Example 1:
Parameters Setting:
Address start=0; Address end=2; Point start=4; Point end=5;
Triggered firing position:
include Slave 0 position 4 to F, Slave 1 position 0 to F, Slave 2
position 0 to 5.
Example 2:
Parameters Setting:
Address start=0; Address end=2; Point start=4; Point end=4;
Triggered firing position:
Slave 0 position 4, Slave 1 position 4 and Slave 2 position 4.
Example 3:
Parameters Setting:
Address start=0; Address end=0; Point start=2; Point end=9;
Triggered firing position:
Slave 0 position 2 to 9.
Effect:
set the firing running rules of the slave. There are five preset firing running rules Left
to Right, Right to Left, Synchronous, Sides to Middle, Middle to Sides.
Interval time (ms):
firing time interval between two igniter on slave.
Group:
Divide Cue list into group.
Select any of the Cue, click to choose this Cue in “Group” column (it will show “
” after
selected), only adjacent Cue can be divided into same group.
Background color is the same for a group Cue.
Cues in different groups will appear in alternative grey and white.
The Cue in same group will triggered together.
Click the “
” to ungroup.
After setting manual fire file, select a CUE, switch ON “Pyro Arm”, hold “Deadman” button
and press “Fire”button, the CUE start firing, and timing start from the moment press “Fire”
button. When current CUE finished, it will jump to next CUE, if want to firing next CUE please
hold “Deadman” and press “Fire”.
Switch off the “Pyro Arm” can terminate the firing CUE.
Note: Manual Firing demonstration mode can be set in setting menu. When not select “Pyro
armed is required for manual fire” means the manual fire demo function was ON, there is no
wireless signal send out after press “Fire”, in this case we can check the igniter status at
“Check” interface.