9
Multiple Shoguns G-40 (
DMX Control
)
1.
Fasten the effect light onto firm trussing (Use a 30-kg rated or stronger C-clamp bolted onto the Showtec
Shogun bracket). Leave at least 0,5 meter on all sides for air circulation.
2.
Use a 3-p XLR cable to connect the Shoguns and other devices.
The pins:
1.
Earth
2.
Signal -
3.
3.
Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
4.
Set DMX dip switches as follows (See Dip Switch setting page 10).
Shogun G-40 Address Value
DMX Dip Switches "ON"
Unit 1
1
#1 and for DMX # 10 and # 12.
Unit 2
11
#1, #2, #4 and for DMX # 10 and # 12.
Unit 3
21
#1, #3, #5 and for DMX # 10 and # 12.
Unit 4
31
#1, #2, #3, #4, #5 and for DMX # 10 and # 12.
5.
Supply electric power: Plug the end of the mains power cord into proper electric power supply sockets.
Do so for all units and the controller. You can control up to 32 Shogun devices in Master-Slave Mode.
DMX-Set up
Master/Slave Set up
Fig. 4
Note : Link all DMX cables and set dip switches before connecting electric power
6.
Do not supply power before the whole system is set up and connected properly.
Design your show according to your DMX controller functions. After every new dipswitch setting you have
to disconnect the power, and then turn the power on to activate the new dipswitch setting.