background image

    

Shogun Club G-40

            

ORDERCODE 32020

Содержание Shogun Club G-40

Страница 1: ...Shogun Club G 40 ORDERCODE 32020 ...

Страница 2: ... 160 31 Muster Dekagramm 161 183 161 183 32 Muster Stern 5 Zacken 184 206 184 206 33 Muster Schnecke 4 207 229 207 229 34 Muster Stern 3 Zacken 230 252 230 252 35 Muster Stern 4 Zacken 253 255 Schnell 253 255 Schnell 36 Muster Stern 6 Zacken 37 Muster Stern 8 Zacken 38 Muster Strich Stern 3 39 Muster Strich Stern 4 Wert Funktion 40 Muster Strich Stern 5 0 10 Normal 41 Muster Strich Stern 6 11 21 N...

Страница 3: ...RY CHRISTMAS 96 Muster Stern 8 Zacken 4 161 Muster Strich Keuz unterbrochen 97 Muster Stern 8 Zacken mit Kreisen 162 Bild Kerze 98 Muster Stern 8 Zacken im 8 Eck 163 Bild Haus 99 Muster Pentagramm 2 164 Bild Umschlag 100 Muster Kleeblatt 165 Bild UFO 101 Muster 5 Kreise im Kreis 166 Bild Kugel 102 Muster Blume 1 167 Bild Schüssel 103 Muster Sonne im Kreis 168 Bild Ziffer 9 104 Muster Halbkreis ges...

Страница 4: ... Bild Dancing Girl 23 224 Bild Dancing Girl 24 225 Bild Dancing Girl 25 226 Bild Dancing Girl 26 227 Bild Dancing Girl 27 228 Bild Dancing Girl 28 229 Bild Dancing Girl 29 230 Bild Dancing Girl 30 231 Bild Dancing Girl 31 232 Bild Dancing Girl 32 233 Bild Dancing Girl 33 234 Bild Dancing Girl 34 235 Bild Dancing Girl 35 236 Bild Dancing Girl 36 237 Bild Dancing Girl 37 238 Bild Dancing Girl 38 239...

Страница 5: ...uct provides the effect you need You can rely on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting equipment Always get the best with Showt...

Страница 6: ...tion Features and Overview Backside Set Up and Operation One Shogun G 40 Stand alone mode One Shogun G 40 Sound Active One Shogun G 40 Auto Mode Multiple Shoguns G 40 Master Slave Multiple Shoguns G 40 DMX Control DMX Dipswitch setting DMX Quick Reference Chart DMX Channels Maintenance Replacing the Fuse Troubleshooting No Light No Response to DMX Product Specifications ...

Страница 7: ...o user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Never unscrew the housing Never aim the laser beam at people or animals Never let the power cord come into contact with other cables Handle the power cord and ...

Страница 8: ...densation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service For adult use only Lighteffect must be installed out of the reach of children Never leave the unit ru...

Страница 9: ...lluminated surface must be more than 0 8 meter The maximum ambient temperature ta must never be exceeded If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc You endanger your own safety and the safety of ...

Страница 10: ...with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the laser always make sure that the area below the installation place is blocked and staying in the area is forbidden Improper installation can cause serious damage to people and property Proper Usage Safety and Compliance Information According to FDA Regulations you should operate this produ...

Страница 11: ...2nm DMX control via standard DMX controller 64 Patterns 10K closed loop scanning pair 10 DMX control channels required 12 channels RGY and RGB units RGY RGY TTL modulation Sound controlled via built in microphone Fuse 2A 250V Overview Fig 1 Frontside Fig 2 1 Power LED 2 Laser indicator LED 3 Microphone 4 Sound Active LED 5 DMX indicator LED ...

Страница 12: ...mitting there is a rattling sound Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Remove the protection cover from the front of the laser When the laser is not in use please replace the cover to protect the laser Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a ...

Страница 13: ...the sensitivity reaction to the music Auto Mode If Dip switches are set to 1000000000 then the fixture will play all pre programmed patterns Multiple Shoguns G 40 Master Slave 1 Fasten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Shogun Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Shoguns and other devic...

Страница 14: ...n G 40 Address Value DMX Dip Switches ON Unit 1 1 1 and for DMX 10 and 12 Unit 2 11 1 2 4 and for DMX 10 and 12 Unit 3 21 1 3 5 and for DMX 10 and 12 Unit 4 31 1 2 3 4 5 and for DMX 10 and 12 5 Supply electric power Plug the end of the mains power cord into proper electric power supply sockets Do so for all units and the controller You can control up to 32 Shogun devices in Master Slave Mode DMX S...

Страница 15: ...address values are determined set the appropriate DMX dip switches on each unit Example 1 If you want to give a Shogun DMX address133 you first have to find the number 133 in the DMX Chart 2 Then look at the left side Dip Switches 1 5 horizontally from 133 In the Table you ll see 1 ON 2 OFF 3 ON 4 OFF 5 OFF 3 Finally look at the upper side of the table Dip Switches 6 9 vertically from 133 In the T...

Страница 16: ...06 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 ...

Страница 17: ...No Turn 64 127 X Coordinate Turn 128 191 Y Coordinate Turn 192 255 X Y Coordinate Turn Channel 6 Partition 0 63 No Partition 64 127 Partition On X Coordinate 128 191 Partition On Y Coordinate 192 255 Partition On X Y Coordinate Channel 7 Static Patterns Pattern Size 0 63 No Partition 64 127 Partition On X Coordinate 128 191 Partition On Y Coordinate 192 255 Partition On X Y Coordinate Channel 8 Sp...

Страница 18: ...All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 2 There may not be any deformations on housings fixations and installation spots 3 The electric power supply cables must not show any damages or material fatigue Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If ...

Страница 19: ...he unit is plugged into an appropriate power supply 2 The laser Return the device to your Showtec dealer 3 The fuse See page 13 for replacing the fuse No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 1 Check the DMX cable Unplug the unit change the DMX cable then reconnect to electrical power Try your DMX control again 2 D...

Страница 20: ...n and Programming DMX Channels 10 Signal input 3 pin XLR male Signal output 3 pin XLR female DMX control via standard DMX controller Laser 40 mW green Laser 532nm Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 0 8m Design and product specifications are subject to change without prior notice ...

Страница 21: ...2006 Showtec ...

Отзывы: