12
Link-Up
This product can work with more than one unit through link-up easily and conveniently. All other link-up
units are controlled by the first one and change of work state set will change all.
There is time-delay with the max. 0.4 sec. change when the function set change is transmitted to the next
unit. All the link-up units have the same function state and work value. Output is the same but not
Synchronous.
1.
Fasten the effect light onto firm trussing (Use a 30-kg rated or stronger C-clamp fastened onto the
Quatro). Leave at least 1 meter on all sides for air circulation.
2.
Plug one end of the electric mains power cord into the IEC socket on the unit
.
Then plug the other end of the cord into a proper electric power supply socket.
3.
Use a 3-p XLR cable to connect the Quatro and other devices.
The pins:
1.
Earth
2.
Signal -
3.
Signal +
Link cables before connecting electric power
Note
1)
Items and Contents shown in Display Segment
Item
Content
MIDI-IN Channel
MIDI Note Number
DMX start channel on receiving signal
Chase or program
Chase speed (max. 99, min. 01)
Dimmer intensity
Normal MIDI Mode
MIDI Note Number start from 36 on receiving
MIDI signal (N:001 is equal to N:036 in normal mode).
2)
Press and hold down
button will quickly increase the value to the Max. Press and hold down
b
utton
will quickly decrease the value to the Min.
3)
Link-up units should not amount too much as there is delay-time when transmitting messages to the
next unit. Otherwise some units would face apparent time delay.