background image

 

OPERATING DETERMINATIONS

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 0.5 meter. 
 
The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 
The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 
 
If this device is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 
 
 

You endanger your own safety and the safety of others!

 

 

 

Rigging 

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the Quadro Flower is lowered from the ceiling or high joists, professional trussing systems have to 
be used. 

 

Use a clamp to mount the Quadro Flower, with the mounting-bracket, to the trussing system. 

 

The Quadro Flower must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 
 

Connection with the mains

 

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

 
 

 
 

Содержание quadro flower v2

Страница 1: ...Quadro Flower V2 ORDERCODE 43028...

Страница 2: ...n and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showt...

Страница 3: ...res and Overview Backside Installation Set Up and Operation Control Modes One Quadro Flower Custom Mode One Quadro Flower Sound Control Multiple Quadro Flowers Master Slave control Multiple Quadro Flo...

Страница 4: ...ng on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intens...

Страница 5: ...the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the lens is obviou...

Страница 6: ...ation yourself Always let the installation be carried out by an authorized dealer Procedure If the Quadro Flower is lowered from the ceiling or high joists professional trussing systems have to be use...

Страница 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 8: ...mpact strong metal housing Power consumption 40 Watt Beam angle 15 Light source 256 LEDs 96 Red 96 Green 64 Blue Music controlled via built in microphone Operating Modes built in programs Auto run DMX...

Страница 9: ...t Up and Operation Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or...

Страница 10: ...nctions as a stand alone device Dipswitch 10 must always be set to OFF for custom control You can set dipswitch 1 2 3 4 5 7 8 or 9 to your desired operating mode Single LED move from left to right and...

Страница 11: ...ve control 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Quadro Flower The pins 1 Earth 2 Signal 3 Signal...

Страница 12: ...proper electric power supply sockets starting with the first unit Do not supply power before the whole system is set up and connected properly Multiple Quadro Flowers DMX Max 30 Quadro Flowers Fig 4 N...

Страница 13: ...41 Explanation Since each unit has 10 channels each address advances 10 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DM...

Страница 14: ...12...

Страница 15: ...er may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Quadro Flowers on a DMX data link 30 fixtures Data Cabling...

Страница 16: ...vement 2 Only works when CH1 is set between 50 99 0 255 Left to right from slow to fast Channel 6 LED movement 3 Only works when CH1 is set between 50 99 0 255 Inside to outside from slow to fast Chan...

Страница 17: ...d fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See th...

Страница 18: ...uilt in programs Auto run Static Color DMX Sound active Master Slave Recall last operation when power is on again Auto running loops selectable Music controlled via built in microphone Fuse 2A 250V Di...

Страница 19: ......

Отзывы: