background image

 

  

 

 

   

 

Ordercode: 50661 

 

Showtec PSA-16A3S 

 

 

Warning 

 

 

 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 

 

Your shipment includes

 

 

Showtec PSA-16A3S 

 

User manual 

 

 

 

Safety Instructions 

Every person involved with the installation, operation and maintenance of this device has to: 

 

be qualified 

 

follow the instructions of this manual 

 

 

 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

 

Содержание PSA-161

Страница 1: ...PSA 16A3S V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50661 MANUAL ENGLISH ...

Страница 2: ...fety Instructions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Maintenance 8 Troubleshooting 8 Product Specification 9 ...

Страница 3: ...ory box and packing Your shipment includes Showtec PSA 16A3S User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the device To...

Страница 4: ... not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged w...

Страница 5: ... void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect the device to the 3 phase Power Socket with a CEE form power plug Always make sure that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L1 BROWN ...

Страница 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of...

Страница 7: ...ct to the three phase mains Make sure that the total load connected to the PSA 16A3S does not exceed 16A per phase The CEE input should be connected to the power source which is equipped with its own RCCB protection 02 16A Schuko output Single phase Schuko output with a maximum load of 16A per socket connected to L1 phase Total load for all sockets together should not exceed 16A per phase 03 L1 Ma...

Страница 8: ...frontside should not exceed 16A per phase 11 Schuko L2 Output Schuko socket Maximum load 1x 16A per socket Total load for both sockets on L2 together should not exceed 16A per phase 12 Schuko L2 Output Schuko socket Maximum load 1x 16A per socket Total load for both sockets on L2 together should not exceed 16A per phase 13 Schuko L3 Output Schuko socket Maximum load 1x 16A per socket Total load fo...

Страница 9: ...points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 The electric power supply cables must not show any damages or material fatigue The Showtec PSA 16A3S requires almost no maintenance However yo...

Страница 10: ...V AC 50 60Hz Circuit breaker 3 x 1 pin 16A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 16A Breaking capacity 6kA Color Dark grey Voltage and amperage indication LED display Cooling Convection Max ambient temperature ta 5 C 35 C Max housing temperature tB 80 C Minimum distance Minimum distance from flammable surfaces 0 5 m Design and product specificat...

Страница 11: ...10 Ordercode 50661 Showtec PSA 16A3S ...

Страница 12: ... 2016 Showtec ...

Отзывы: