background image

 

12 

Control Panel 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 
 
 
 
 
 
 
 

A.

 LCD Display  

 

D.

 Down Button 

B.

 MODE/ESC button   

E.

 ENTER Button 

C.

 Up Button   

 

 

Control Mode  

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address the next time.)

 

 

DMX Addressing

 

The control panel on the front side of the base allows you to assign the DMX fixture address, which is the 
first channel from which the Phantom will respond to the controller. 
Please note when you use the controller, the unit has 

12

 channels. 

When using multiple Phantoms, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Phantoms should be 

1(d001)

; the DMX address of the second 

Phantom  
should be 

1+12=13 (d013

); the DMX address of the third Phantom should be 

13+12=25 (d025)

, etc. 

Please, be sure that you don’t have any overlapping channels in order to control each Phantom 
correctly. 
If two or more Phantoms are addressed similarly, they will work similarly.

 

For address settings, please refer to the instructions under ”Addressing’.

 

 

Controlling: 

After having addressed all Phantom fixtures, you may now start operating these via your lighting 
controller.

 

Note:

 After switching on, the Phantom will automatically detect whether DMX 512 data is received or 

not. If there is no data received at the DMX-input, the “

LED

 “ on the control panel will not flash.

 

If not, the problem may be:

 

 

The XLR cable from the controller is not connected with the input of the Phantom.

 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 
Note: 

It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  
 
 

 

Содержание phantom 75 LED

Страница 1: ...Phantom 75 LED Beam ORDERCODE 40190 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Страница 3: ...MX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 DMX Addressing 14 Built in Programs Mode 15 Pan movement Mode...

Страница 4: ...tly reduced If improving your lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overal...

Страница 5: ...ug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rea...

Страница 6: ...afety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let th...

Страница 7: ...ith the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN R...

Страница 8: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 9: ...ainbow flow effect Rotating Gobowheel with 6 metal gobos and open with Gobo Shake Function No replaceable gobos Rotation Bi directional Prism 3 facet prism Gobo functions Gobo flow effect Gobo shake 8...

Страница 10: ...ly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they...

Страница 11: ...evice Turn on the music If the device is set to sound control then the Phantom will react to the beat of the music Please see page 15 for more information about the sound control options Multiple Phan...

Страница 12: ...l cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into e...

Страница 13: ...Maximum recommended DMX data link distance 100 meters Maximum recommended number of Phantoms on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can p...

Страница 14: ...3 the DMX address of the third Phantom should be 13 12 25 d025 etc Please be sure that you don t have any overlapping channels in order to control each Phantom correctly If two or more Phantoms are ad...

Страница 15: ...13 Menu Overview...

Страница 16: ...s Pan 540 360 180 Tilt 270 180 90 Reset Load factory default settings DMX Addressing With this menu you can set the DMX address 1 Press Mode Esc until the display shows 2 Press Enter to confirm You ca...

Страница 17: ...lay will show The device is now a slave device It will now react the same as its master Pan movement Mode When the display shows the device is in normal Pan Mode When you press Up Down The display wil...

Страница 18: ...s ENTER the device will return to the factory default settings Password Change This is a Service Function Press and hold MODE ESC for 2 seconds The display will show 0000 Press the Up button to change...

Страница 19: ...so called Rainbow effect 0 6 Open White 7 13 Yellow 14 20 Pink 21 27 Green 28 34 Red 35 41 Light Blue 42 48 Light Green 49 55 Orange 56 63 Dark Blue 64 70 Split Color White Yellow 71 77 Split Color Y...

Страница 20: ...ovement 56 95 No Function 96 103 Reset Pan 104 111 Reset Tilt 112 119 Reset Colorwheel 120 127 Reset Gobowheel 128 135 No Function 136 143 Reset Prism 144 151 No Function 152 159 Reset All channels 16...

Страница 21: ...r Green Red 92 98 Split Color Red Light Blue 99 105 Split Color Light Blue Light Green 106 112 Split Color Light Green Orange 113 119 Split Color Orange Dark Blue 120 127 Split Color Dark Blue White 1...

Страница 22: ...echanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue The Showtec Phantom 75 LED Beam...

Страница 23: ...y out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technici...

Страница 24: ...d with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and d...

Страница 25: ...t colors Rainbow flow effect Rotating Gobowheel with 6 metal gobos and open with Gobo Shake Function No replaceable gobos Rotation Bi directional Prism 3 facet prism Gobo functions Gobo flow effect Go...

Страница 26: ......

Отзывы: