SHOWTEC Performer 60 LED Скачать руководство пользователя страница 1

 

 
 
 
 
 
 
 
 
 
 

 

 

Performer 60 LED                   V3 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Ordercode: 33100 

MANUAL 

ENGLISH 

Содержание Performer 60 LED

Страница 1: ...Performer 60 LED V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33100 MANUAL ENGLISH ...

Страница 2: ...er mode 10 One Performer Sound controlled 10 Multiple Performers Master Slave control 10 Multiple Performers DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 14 1 Show Mode 15 2 Slave Mode 15 3 DMX Addressing DMX Configuration 15 4 Sound controlled Mode 15 5 Dimmer Mode 15 6 Settings 16 7 Info 17 DMX Channels 17...

Страница 3: ...tec Performer 60 LED 1 x filter frame PowerCON to Schuko power cable 1 5m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest...

Страница 4: ... not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Alw...

Страница 5: ...is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attemp...

Страница 6: ...ht color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always properly connected to the earth Improper installation can cause serious injuries and or damage of property ...

Страница 7: ...umber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of me...

Страница 8: ... Strobe 0 20Hz Refresh rate 2 kHz Beam angle 8 45º Control modes Auto Dimmer Sound controlled Master Slave DMX 512 LCD display for easy setup Connections 3 pin XLR signal connectors IN OUT PowerCON power connectors IN OUT DMX channels 1 or 3 channels Housing Die cast aluminum flame retardant plastic Cooling Forced cooling IP rating IP20 Fuse T1L 250V Dimensions 285 x 250 x 300 mm LxWxH Weight 4 8 ...

Страница 9: ... LCD display control buttons 05 Adjustment screw 06 Ground earth connection 07 Fuse T1L 250V 08 PowerCON power connector 100 240V IN 09 PowerCON power connector 100 240V OUT 10 3 pin DMX signal connector IN 11 3 pin DMX signal connector OUT 12 Safety eye ...

Страница 10: ... Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply Color Frame Retaining Clip The color frame holder is equipped with a spring loaded retaining clip This prevents color frames and accessories from falling out Make ...

Страница 11: ...oper electric power supply socket 04 Turn on the music The Performer will react to the beat of the music Please see page 15 for more information about the sound control options Multiple Performers Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the elec...

Страница 12: ...Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second and third units 05 Supply electric power Plug electric mains power cords into each unit s PowerCON socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before the whole s...

Страница 13: ...urchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL01...

Страница 14: ...ase make sure that you do not have any overlapping channels in order to control each Performer correctly If two or more Performers are addressed similarly they will work similarly Controlling After having addressed all Performer fixtures you may now start operating these via your lighting controller Note After switching on the Performer will automatically detect whether DMX 512 data is received or...

Страница 15: ...former 60 LED Menu Overview Main Menu Options 1 Auto show 2 Slave mode 3 DMX addressing DMX configuration 4 Sound controlled mode 5 Dimmer mode 6 Settings 7 Info On start up the device will show the current software version ...

Страница 16: ... set the DMX address and control the DMX configuration 01 Press the MODE button until the display shows 02 Press the SETUP button to open the menu You can choose 512 different DMX addresses 03 Press the UP DOWN buttons to select the required address from Once you have set the desired DMX address you can also set the DMX mode 04 Press the SETUP button again to proceed to the channel mode settings 0...

Страница 17: ...en the menu 03 Press the UP DOWN buttons to choose from the 6 available submenus and 04 Press the SETUP button to open one of the 6 submenus 05 In you can select one of the 4 dimming curves by pressing the UP DOWN buttons 06 With the menu you can set the dimmer speed by pressing the UP DOWN buttons You can choose SMOOTH or FAST ...

Страница 18: ...r choice 15 In you can set synchronous DMX 16 Press the SETUP button to open the menu and then press the UP DOWN buttons to choose ON or OFF 17 If you choose ON you activate the tool which helps to keep multiple fixtures synchronized when using them in master slave mode even after a certain amount of time 18 Press the SETUP button to confirm your choice 7 Info 01 Press the MODE button until the di...

Страница 19: ...mp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly Please clean internal components once a year with a light brush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe the DMX and ...

Страница 20: ...placing the fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Performer as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer No Response to DMX Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 01 Check the...

Страница 21: ...ctions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is restored...

Страница 22: ...mer 0 100 Dimming curve 4 presets Strobe 0 20Hz Refresh rate 2 kHz Color temperature 3200K Housing Die cast aluminium flame retardant plastic DMX control via standard DMX controller Onboard LCD display for easy setup Control Auto Dimmer Sound controlled Master Slave DMX 512 Connections PowerCON IN OUT to Schuko dedicated data connector IP rating IP20 Cooling Forced cooling Max ambient temperature ...

Страница 23: ...22 Ordercode 33100 Performer 60 LED Dimensions ...

Страница 24: ... 2017 Showtec ...

Отзывы: