SHOWTEC Expression 600Z Скачать руководство пользователя страница 14

 

  

  

13 

 

 

 

Ordercode: 41393 

Expression 600Z 

The Expression 600Z can be operated with a controller in 

control mode

 or without the controller in  

stand-alone mode. 

 

Control Panel 

 

 

A) MENU 

button 

B) ENTER 

button 

C) DOWN 

button 

D) UP 

button 

E)   LCD display 
 

 
 

Fig. 05 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  

The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address, next time.) 

 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first 

channel with which the Expression will respond to the controller. 

Please note, when you use the controller, the unit has 

20

 channels. 

When using multiple Expressions, make sure you set the DMX addresses right. 

Therefore, the DMX address of the first Expression should be 

1(001)

; the DMX address of the second 

Expression should be 

1+20=21 (021)

; the DMX address of the third Expression should be 

21+20=41 (041)

etc. Please, be sure that you do not have any overlapping channels in order to control each Expression 

correctly. If two or more Expressions are addressed similarly, they will work similarly. 

 

Controlling: 

After having addressed all Expression fixtures, you may now start operating these via your lighting 

controller.

 

Note:

 After switching on, the Expression will automatically detect whether DMX 512 data is received or 

not. If there is no data received at the DMX-input, the “

LED

 “ on the control panel will not flash. 

If not, the problem may be:

 

 

The XLR cable from the controller is not connected with the input of the Expression 600Z.

 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 

swapped in the input connector. 

 

Note: 

It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  
 

 

Display Off after 30 seconds

 

When no button is pressed for 30 seconds, the display will turn off. 
To light up the display, you have to press the MENU, ENTER, UP or DOWN button. 

Once you have pressed the button, the display will light up. 

 

 

Содержание Expression 600Z

Страница 1: ...Expression 600Z V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 41393 MANUAL ENGLISH...

Страница 2: ...Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overview 14 Main Menu Options 15 1 Address 15 2 Personality 16 3 Perform 16 3 1 Fans 16 3 2 Pan Tilt 16 3 3 Blackout 16 3 4 Dim...

Страница 3: ...code 41393 Expression 600Z 20 channels PERSON2 25 14 channels CMY 27 Maintenance 29 Replacing the Fuse 29 Troubleshooting 29 No Light 29 No Response to DMX 29 Product Specifications 31 Dimensions 32 N...

Страница 4: ...udes Showtec Expression 600Z Mounting bracket with quick locks User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the accelerati...

Страница 5: ...force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and al...

Страница 6: ...temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dang...

Страница 7: ...n with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELL...

Страница 8: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Страница 9: ...540 Tilt 270 Housing Metal flame retardant plastic Connections 3 pin 5 pin XLR data connectors PowerCON power connector IN OUT IP rating IP20 Fuse T3 15AL 250V Dimensions 245 x 240 x 395 mm LxWxH Wei...

Страница 10: ...ding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages...

Страница 11: ...mode CUSTOM Multiple Expressions Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin 5 pin XLR cable to connect...

Страница 12: ...onnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric ma...

Страница 13: ...s on a power link 240V 18 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct yo...

Страница 14: ...of the third Expression should be 21 20 41 041 etc Please be sure that you do not have any overlapping channels in order to control each Expression correctly If two or more Expressions are addressed s...

Страница 15: ...14 Ordercode 41393 Expression 600Z Menu Overview...

Страница 16: ...s to toggle between the two screens 03 Press the ENTER button to open the main menu 04 Press the UP DOWN buttons to toggle through the main menu options 05 Press the ENTER button to open the desired s...

Страница 17: ...ve chosen AUTO the fan speed will depend on the device s current temperature and will be adjusted automatically 3 2 Pan Tilt 01 Press the UP DOWN buttons to choose between PAN INVERT pan inversion TIL...

Страница 18: ...is pressed for 30 seconds 04 If you have chosen LONG the display will remain continuously on 3 9 Display Lock 01 Press the UP DOWN buttons to choose between ON and OFF 02 Press the ENTER button to co...

Страница 19: ...t will be necessary to insert the password The password can be inserted by pressing the buttons in the following order UP DOWN UP DOWN and ENTER to confirm 3 11 4 Wireless DMX Hide 01 Press the UP DOW...

Страница 20: ...he master device 02 Press the ENTER button to confirm your choice 4 2 Edit With this menu you can create your own custom show consisting of a maximum of 50 steps 01 Once you have entered EDIT menu the...

Страница 21: ...menu you can monitor the device s current temperature error log and software version 01 Press the UP DOWN buttons to toggle between the following menus 02 If you have chosen SYSTEM ERROR press the EN...

Страница 22: ...ween PAN and TILT 02 Press the ENTER button to open 03 Press the UP DOWN buttons to calibrate pan or tilt The adjustment range is between 0 255 7 2 RGBtoW 01 Press the UP DOWN buttons to choose betwee...

Страница 23: ...0 255 From fast to slow Channel 6 Continuous Pan 0 Not functional 1 127 Clockwise rotation from slow to fast 128 254 Counterclockwise rotation from fast to slow 255 Stop Channel 7 Dimmer 0 255 Dimmer...

Страница 24: ...Pan Move the slider up in order to move head horizontally PAN Gradual head adjustment from one end of the slider to the other 0 255 The head can be turned by 540 and stopped at any position you wish C...

Страница 25: ...00 White 100 190 199 2700K 200 209 3200K 210 219 4200K 220 229 5600K 230 239 6500K 240 255 8000K Channel 13 Strobe Dimmer must be open 0 10 Not functional 11 109 Pulse strobe from low to high frequenc...

Страница 26: ...ed 0 255 From fast to slow Channel 6 Continuous Pan 0 Not functional 1 127 Clockwise rotation from slow to fast 128 254 Counterclockwise rotation from fast to slow 255 Stop Channel 7 Red Dimmer must b...

Страница 27: ...200 209 3200K 210 219 4200K 220 229 5600K 230 239 6500K 240 255 8000K Channel 18 Strobe Dimmer must be open 0 10 Not functional 11 109 Pulse strobe from low to high frequency 110 255 Random strobe fro...

Страница 28: ...ise rotation from slow to fast 128 254 Counterclockwise rotation from fast to slow 255 Stop Channel 7 Cyan Dimmer must be open 0 255 Gradual adjustment Cyan from 0 100 Channel 8 Magenta Dimmer must be...

Страница 29: ...ons Dimmer must be open 0 9 Not functional 10 19 Pan tilt blackout ON after 5 seconds 20 29 Pan tilt blackout OFF after 5 seconds 30 39 Fan speed SLOW 40 49 Fan speed NORMAL 50 59 Fan speed FAST 60 69...

Страница 30: ...s out the product will not function whatsoever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a flat head screwdriver into a slot in the fuse cover...

Страница 31: ...connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on th...

Страница 32: ...ltichip RGBW Light output 2578 lumen Motorized zoom 4 5 45 Pan Tilt range 540 270 Dimmer 0 100 Strobe 0 20Hz Housing Metal flame retardant plastic DMX control via standard DMX controller Onboard LCD d...

Страница 33: ...32 Ordercode 41393 Expression 600Z Dimensions...

Страница 34: ...33 Ordercode 41393 Expression 600Z Notes...

Страница 35: ...34 Ordercode 41393 Expression 600Z...

Страница 36: ...2016 Showtec...

Отзывы: