SHOWTEC Explorer 575 Spot Скачать руководство пользователя страница 5

3

  Only use device indoor, avoid contact with water or other liquids.

  Only operate the fixture after having checked that the housing is firmly closed and all screws are

tightly fastened.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  To ensure the longest and most efficient use of the lamp always wait 15 minutes before re-applying

power after a shutdown. Failure to do so could result in premature aging of the lamp and failure to
the electronics that drive it.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Movinghead must be installed out of the reach of children. Never leave the unit

running unattended.

  Never attempt to bypass the thermostatic switch or fuses.

  For replacement use lamps and fuses of same type and rating only.

  Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service

life.

  Allow the fixture to cool down for 15 minutes, before opening the fixture and replacing lamp. Protect

your hands and eyes with gloves and safety glasses.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

The minimum distance between light-output and the illuminated surface must be more than 2 meters.

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Содержание Explorer 575 Spot

Страница 1: ...Explorer 575 Spot ORDERCODE 40191...

Страница 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Страница 3: ...es and Overview Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Explorer Multiple Explorers DMX Protocol Control Panel Control Mode DMX addressing Stand alone mode F...

Страница 4: ...caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any ho...

Страница 5: ...n exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has...

Страница 6: ...tion yourself Always let the installation be carried out by an authorized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have to be used Use...

Страница 7: ...ous damage to people and property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place Wire Col...

Страница 8: ...3200 K 6000 K and open 1 Rotating Gobo wheel with 3 glass and 3 metal interchangeable rotating gobos plus open 1 Static Gobo wheel with 9 gobos plus open DMX control via standard DMX controller 16 DM...

Страница 9: ...7 Backside 4 5 6 7 Fig 2 4 DMX signal connector OUT 5 DMX signal connector IN 6 ON OFF 7 Fuse...

Страница 10: ...amps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 3 screws X Y Z on the backside of t...

Страница 11: ...istance between the lamp and the lens was already set during the installation with screw A only the Hot Spot the brightest part of the ray of light must be centered Turn in addition screw B and C If t...

Страница 12: ...4 Use the Mode button to set the fixture to RUN and choose PR6 1 The Explorer will now play its built in program Multiple Explorers 1 Fasten the moving head onto firm trussing Use a clamp ordercode 70...

Страница 13: ...an be turned by 530 and stopped at any position you wish Channel 2 Vertical movement Tilt Push the slider up in order to move head vertically TILT Gradual head adjustment from one end of the slider to...

Страница 14: ...effect from fast to slow Channel 8 Static Color wheel 0 25 Open white 26 51 Light Red 52 77 Pale Yellow 78 103 Light Purple 104 129 Pale Green 130 155 Light Orange 156 181 Sky Blue 182 207 Light Blue...

Страница 15: ...ter strobe 0 19 Shutter 20 250 Strobe effect from slow to fast 251 255 Beam out Channel 16 Lamp ON OFF Reset dimmer 0 29 No Function 30 39 Lamp on after 3 seconds Reset 40 59 No Function 60 69 Lamp of...

Страница 16: ...xplorer should be 1 16 17 A017 the DMX address of the third Explorer should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to control each Explorer correctly...

Страница 17: ...also be used for strobe effect 1 10 flashes per second Stand alone Mode The fixture can execute 1 pre set program Use the Mode button to set the fixture to RUN and choose PR6 1 The Explorer will now...

Страница 18: ...16 Channel settings...

Страница 19: ...ght output very quickly The cooling fans dichroic colour filters the gobo wheels the gobos and the internal lenses should be cleaned monthly with a soft brush To ensure proper functioning of the gobow...

Страница 20: ...u want to remove to the upside 5 Very carefully take the pinchcock fig 13 and 14 out of the gobo wheel but pay attention that the pinchcock does not fall in the device Then push the gobo out 6 Place t...

Страница 21: ...supply 2 The lamp Replace the old lamp with a new one with the same specifications See page 8 for replacing lamps 3 The fuse Replace the fuse See page 17 for replacing the fuse No Response to DMX Res...

Страница 22: ...ing One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly togethe...

Страница 23: ...tic Gobo wheel with 9 gobos plus open Colour wheel with variable rotation speed Prism 3 facer prism rotating All lenses are anti reflection coated High luminous efficiency parabolic system Strobe effe...

Страница 24: ...2006 Showtec...

Отзывы: