background image

 

  

 

 

   

 

Ordercode: 43165 

Energetic 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. (T

his distance may differ depending on the model. The exact minimum distance will be 

mentioned in the corresponding manual.)

 

 

To eliminate wear and improve lifespan, during periods of non-use, completely disconnect from 
power via breaker or by unplugging. 

 

The maximum ambient temperature t

a

 = 35°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 35°C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 

Laser safety for a Class 3R Laser Product 

Laser Light is different from any other light source with which you may be familiar with. This laser is less 
dangerous than a higher class laser such as an 3B or 4. The light from this product is safe for unintentional 
(<1/4 sec) unaided eye exposure. However this device is potentially hazardous if viewed with certain 
optical instruments such as binoculars or eye loupe. 
Laser light is thousands of times more concentrated than light from any other kind of light source. This 
concentration of light power can cause instant eye injuries, primarily by burning the retina (the light 
sensitive portion at the back of the eye). Even if you cannot feel “heat” from a laser beam, it can still 
potentially injure or blind you or your audience.  
Even very small amounts of laser light are potentially hazardous even at long distances. Laser eye injuries 
can happen quicker than you can blink.  
It is incorrect to think that because these laser products split the laser into hundreds of beams or the laser 
beam is scanned out in high speed, that an individual laser beam is safe for eye exposure. This laser 
product uses dozens of milliwatts of laser power (Class 3R levels internally). Many of the individual beams 
are potentially hazardous to the eyes.  
 
It is also incorrect to assume that because the laser light is moving, it is safe. This is not true. Nor, do the 
laser beams always move. Since eye injuries can occur instantly, it is critical to prevent the possibility of 
any direct eye exposure. According to the laser safety regulation, it is not legal to aim Class 3R lasers in 
areas which people can get exposed. This is true even if it is aimed below people’s faces, such as on a 
dance floor. 
 
CAUTION! Only Laser Safety Officers who are officially certified by a regulatory body or authorized 
training organization are allowed to use class 3R lasers in public. The Laser Safety Officer is responsible for 
all aspects when using this laser, including following all locally applicable safety laws and regulations.  
The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 
this laser. 
 

 

CAUTION: AVOID EXPOSURE TO BEAM: Avoid direct eye contact with laser 
light. Never intentionally expose your eyes or others to direct laser 
radiation. 

 
Compliance Statement 
Your Energetic laser has been designed to comply with FDA and IEC Standards for its classification.  
The Energetic is a Class 3R laser product. 
 
Laser Safety and Compliance Information 
The Energetic is manufactured to comply with the IEC 60825-1 and in accordance with U.S. Food and 
Drug Administration (FDA) Standards Listed under FDA Document 21 CFR 1040 and subsequent laser 
notices. 
 

 

Содержание Energetic V1

Страница 1: ...Energetic V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43165 MANUAL ENGLISH...

Страница 2: ...Sound controlled 12 Multiple Energetics Master Slave control 13 Multiple Energetics DMX Control 14 Fixture Linking 15 Data Cabling 15 Control Panel 16 Control Mode 16 DMX Addressing 16 Menu Overview 1...

Страница 3: ...power cable 1 5 m 2 keys for the interlock Remote control plug IR remote control User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that lead...

Страница 4: ...point a laser at aircraft this is a federal offense Never point unterminated laser beams into the sky Never open the laser housing The high laser power levels inside of the protective housing can sta...

Страница 5: ...after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device...

Страница 6: ...r your audience Even very small amounts of laser light are potentially hazardous even at long distances Laser eye injuries can happen quicker than you can blink It is incorrect to think that because t...

Страница 7: ...agencies military and others require all lasers to be used under the guidelines of ANSI Z136 1 Laser Display guidance can be obtained via the International Laser Display Association www ilda com inde...

Страница 8: ...net or safety cable When rigging derigging or servicing the Energetic always make sure that the area below the installation site is secured and that there are not any unauthorized people around The E...

Страница 9: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Страница 10: ...IP20 Housing Die cast black aluminum Cooling Cooling fan Connections IEC connectors IN OUT 3 pin XLR IN OUT Fuse T1L 250V Dimensions 260 x 190 x 188 mm LxWxH Weight 1 8 kg LED effect Light source 1 x...

Страница 11: ...stment screw Backside Fig 03 07 Sound sensitivity control 08 Safety eye 09 Ground earth connection 10 IEC power connector OUT 11 IEC power connector IN Fuse T1L 250V 12 3 pin DMX signal connector OUT...

Страница 12: ...roduct specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply The device can be sound controlled as it is...

Страница 13: ...air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Energetic is not connected w...

Страница 14: ...he units as shown in Fig 06 connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second and third units You can use the same f...

Страница 15: ...nnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second and third units 05 Supply electric power Plug electric mains powe...

Страница 16: ...obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables th...

Страница 17: ...getic should be 1 001 the DMX address of the second Energetic should be 1 9 10 010 the DMX address of the third Energetic should be 10 9 19 019 etc Please be sure that you do not have any overlapping...

Страница 18: ...etic Menu Overview The Energetic will only show its version number at start up Main Menu Options 2 channel mode 9 channel mode Static colors Built in programs Program speed Sound controlled Manual IR...

Страница 19: ...ce 4 Built in Programs With this menu you can set the built in programs 01 Press the MODE button until the display shows 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to choo...

Страница 20: ...adual adjustment blue intensity 0 255 Gradual adjustment white intensity 0 255 Strobe speed from slow to fast 04 Press the UP DOWN buttons to change the values 05 Press the ENTER button to save change...

Страница 21: ...he device receives a sound signal the Music LED indicator at the backside will blink Green LED LED auto mode Press the button to activate deactivate the LED program Strobe auto mode Repeatedly press t...

Страница 22: ...4 LEDs laser strobe 45 79 LEDs strobe 80 114 LEDs laser 115 149 Laser strobe 150 184 LEDs 185 219 Strobe 220 255 Laser Channel 2 Built in Program Speed Programs CH1 must be set between 10 255 0 250 Gr...

Страница 23: ...1 from slow to fast 120 129 Pattern 12 from slow to fast 130 139 Pattern 13 from slow to fast 140 149 Pattern 14 from slow to fast 150 159 Pattern 15 from slow to fast 160 169 Pattern 16 from slow to...

Страница 24: ...echnical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or parts of the...

Страница 25: ...the DMX cable then reconnect to electrical power Try your DMX control again 03 Determine whether the controller or light effect is at fault Does the controller operate properly with other DMX product...

Страница 26: ...ot terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is def...

Страница 27: ...er 130mW 100mW 650nm Red 30mW 532nm Green Laser Class 3R Safety Features Key switch Interlock Safety eye Laser Safety EN IEC 60825 1 Ed 2 2007 03 Strobe effect 16 x 0 5W White 5730 LEDs Housing Die ca...

Страница 28: ...27 Ordercode 43165 Energetic Dimensions...

Страница 29: ...28 Ordercode 43165 Energetic Notes...

Страница 30: ...29 Ordercode 43165 Energetic...

Страница 31: ...30 Ordercode 43165 Energetic...

Страница 32: ...2018 Showtec...

Отзывы: