SHOWTEC Datamoon LED Скачать руководство пользователя страница 7

 

      Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 
 
 
 
 
 

Содержание Datamoon LED

Страница 1: ...Datamoon LED ORDERCODE 43046 ...

Страница 2: ...n and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting equipment Always get the best with Showtec Thank you ...

Страница 3: ... Datamoon LED Product Guide Warning Safety instructions Operating Determinations Rigging Return Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Maintenance Troubleshooting No Light Product Specifications ...

Страница 4: ...your dealer and do not use the device To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technici...

Страница 5: ... replaced So that its functions are not impaired due to cracks or deep scratches If device is dropped or struck disconnect mains power supply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave...

Страница 6: ...llation yourself Always let the installation be carried out by an authorized dealer Procedure If the Datamoon LED is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Datamoon LED with the mounting bracket to the trussing system The Datamoon LED must never be fixed swinging freely in the room The installation must always be secured with ...

Страница 7: ... description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is ...

Страница 8: ... system 2 pcs 9 Watt RGB Chip on board Music controlled via built in microphone When no music is played the LEDs and DC Motor turn off after 10 seconds Fuse 1A 250V Overview 1 Fig 1 Backside Fig 2 1 Mountingbracket 5 Fuse 1A 250V 2 Built in microphone 6 Earth connection 3 Gobo Continuous Static Sound active 7 Power cable 4 Mirror Dish Continuous Static Sound active ...

Страница 9: ... Mirror Dish rotates continuously When the switch is set to O the Mirror Dish does not rotate When the switch is set to the device is in music mode and the Mirror Dish reacts to the music Maintenance The Showtec Datamoon LED requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantly reduced Disconnect the mains power supply and ...

Страница 10: ...ntil a solution is found Once the unit operates properly do not carry out following steps 1 If the device does not operate properly unplug the device 2 Check the power from the wall the fuse all cables etc 3 If all of the above appears to be O K plug the unit in again 4 If you are unable to determine the cause of the problem do not open the Datamoon LED as this may damage the unit and the warranty...

Страница 11: ...a built in microphone When no music is played the LEDs and DC Motor turn off after 10 seconds Fuse 1A 250V Dimensions 307x280x140mm LxWxH Weight 3 72 kg Minimum distance Minimum distance from flammable surfaces 0 5m Minimum distance to lighted object 0 8m Design and product specifications are subject to change without prior notice Website www Showtec info Email service highlite nl 7 8 ...

Страница 12: ......

Отзывы: