The user is responsible for correct positioning and operating of the Compact Par 7/15 Q4. The 
manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 
this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

 

You endanger your own safety and the safety of others! 

 

Rigging 
Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer ! 

 

Procedure: 

 

If the Compact Par is lowered from the ceiling or high joists, professional trussing systems have to be 
used. 

 

Use a clamp to mount the Compact Par, with the mounting bracket, to the trussing system. 

 

The Compact Par must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety cable. 

 

When rigging, derigging or servicing the Compact Par, always make sure, that the area below the 
installation site is secured and that there are not any unauthorized people around. 

 

 

Содержание Compact Par 7/15 Q4

Страница 1: ...Compact Par 7 15 Q4 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42599 MANUAL ENGLISH...

Страница 2: ...ltiple Compact Pars Master Slave control 9 Multiple Compact Pars DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options...

Страница 3: ...mpact Par 7 15 Q4 ProPower cable 1 4 m Accessory holder incl screws Filter frame User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads...

Страница 4: ...efore handling Do not shake the device Avoid brute force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after ha...

Страница 5: ...never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer...

Страница 6: ...with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLO...

Страница 7: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Страница 8: ...or easy setup Light source 7 x 15W RGBW LEDs Output 2m 8950lux Control modes Auto Sound controlled Static color Master Slave DMX Control protocol DMX 512 Dimmer 0 100 Strobe 0 5 10Hz Beam Angle 15 Pro...

Страница 9: ...foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning...

Страница 10: ...electric mains power cord into a proper electric power supply socket 04 Turn on the music If the device is set to sound control then the Compact Par will react to the beat of the music Please see pag...

Страница 11: ...nnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mai...

Страница 12: ...obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables th...

Страница 13: ...uld be 11 10 21 021 etc Please be sure that you do not have any overlapping channels in order to control each Compact Par correctly If two or more Compact Pars are addressed similarly they will work s...

Страница 14: ...13 Ordercode 42599 Compact Par 7 15 Q4 Menu Overview The Compact Par will show the following screens at start up First screen Second screen last operation mode...

Страница 15: ...wn buttons to choose between 5 types of built in programs 04 Choose the desired built in program 05 Press the Enter button again to adjust the speed of the built in program 06 Press the Up and Down bu...

Страница 16: ...u the display shows 03 Press the Enter button again to enter the submenu 04 Press the Up and Down buttons to adjust the sensitivity 05 The adjustment range is between 06 Turn on the music and the Comp...

Страница 17: ...r button to open the menu 03 Press the Up and Down buttons to set the desired DMX address 04 The adjustment range is between 8 DMX configuration With this menu you can set the desired DMX configuratio...

Страница 18: ...Dimmer intensity 0 255 Gradual adjustment Blue from 0 100 Channel 4 White Dimmer intensity 0 255 Gradual adjustment White from 0 100 6 channels Channel 1 Red Dimmer intensity CH5 must be set between 1...

Страница 19: ...intensity CH1 must be set between 1 255 0 255 Gradual adjustment White from 0 100 Channel 6 RGBW Fade CH1 must be set between 1 255 0 255 Gradual adjustment from Red to RGBW Channel 7 Strobe CH1 and...

Страница 20: ...llow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push...

Страница 21: ...ctions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the lin...

Страница 22: ...t 3 pin 5 pin DMX OUT Electro mechanical effects LED Quantity 7 x 15W RGBW LED Output 2m 8950lux Color mixing RGBW Beam angle 15 Dimmer 0 100 Strobe 0 5 10Hz Housing Die cast black aluminum DMX contro...

Страница 23: ...22 Ordercode 42599 Compact Par 7 15 Q4 Dimensions...

Страница 24: ...2017 Showtec...

Отзывы: