Description of the device 

 

Features 

The Showtec PSA-32A12M is a power distributor providing real-time voltage and amperage information 
during your show. 
 

 

Power distributor for 3P+ N + PE 400VAC, 32A max 

 

Road suited housing and components 

 

Power supply: 400V 50Hz/60Hz 

 

Digital voltage & amperage monitoring per phase 

 

Input: 1,5m H07RN-F 5G6 cable + CEE male 3P+N+PE 

 

1 x 16A Schuko output (on the front panel) 

 

6 x 16A Schuko output, (on the rear panel) 

 

2 x Multipin 6x10A (on the rear panel) 

 

12 x 1-pin 16A, C-Type circuit breaker (MCB) 

 

A-Type, 30 mA Residual Current Circuit breaker (RCCB) 

 

Housing Material: Powder–coated metal 

 

Color: Dark grey 

 

Dimensions: 

483 x 198 x 176 mm (LxWxH) 
19 inch x 4HE (LxH) 

 

Weight: 9,70 kg 

 

Frontside 

 

 

Fig.01 

 
01)

 

Residual Current Circuit Breaker (RCCB)

 

It will disconnect the device from the mains if a difference between phase (“hot” or “live”) and 
neutral is detected. 

02)

 

Phase L1 Main Circuit Breakers (MCB) 1 - 4

 

Each output has its own circuit breaker. Make sure the total load per circuit breaker does not 
exceed 16A and the total load per phase does not exceed 32A. 

 

 

Содержание 50665

Страница 1: ...Showtec PSA 32A12M V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50665 MANUAL ENGLISH...

Страница 2: ...terminations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Multiconnector outpu...

Страница 3: ...king Your shipment includes Showtec PSA 32A12M with the power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be...

Страница 4: ...not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device...

Страница 5: ...oduct may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others C...

Страница 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Страница 7: ...output on the rear panel 2 x Multipin 6x10A on the rear panel 12 x 1 pin 16A C Type circuit breaker MCB A Type 30 mA Residual Current Circuit breaker RCCB Housing Material Powder coated metal Color D...

Страница 8: ...splay 08 L3 voltage amperage LED display Backside Fig 02 09 Schuko output Maximum load 16A Total load for all sockets on L1 together should not exceed 32A per phase 10 Schuko output Maximum load 16A T...

Страница 9: ...ment into a 19 inch rack Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Oper...

Страница 10: ...lmost no maintenance However you should keep the unit clean 01 Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Do not use alcohol or solvents 02 Pl...

Страница 11: ...ko socket P N PE Circuit breaker MCB 12 x 1 pin 16A C Type Residual Current Circuit breaker RCCB 30 mA A Type Electro mechanical effects IP Rating IP20 Housing Road suited Components Road suited Housi...

Страница 12: ...11 Ordercode 50665 Showtec PSA 32A12M Dimensions...

Страница 13: ...12 Ordercode 50665 Showtec PSA 32A12M Notes...

Страница 14: ...13 Ordercode 50665 Showtec PSA 32A12M...

Страница 15: ...14 Ordercode 50665 Showtec PSA 32A12M...

Страница 16: ...2016 Showtec...

Отзывы: