background image

 

Ordercode: 43630 

Spectral M950 SW 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 

without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 

Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 

return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 

customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 

product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 

 

Note: If you are given an RMA number, please include the following information on a piece of paper 

inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-

comings and/or visible defects, or perform this check after our announcement that the goods are at their 

disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. 

 It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is 

damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 

of the delivery.  

Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 

a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 

agreed otherwise in writing. 

Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of 

the invoice. After this period complaints will not be handled anymore. 

Complaints will only then be considered if the client has so far complied with all parts of the agreement, 

regardless of the agreement from which the obligation is resulting.  

 

 

  

 

 

   

 

Содержание 43630

Страница 1: ...Spectral M950 SW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43630 MANUAL ENGLISH...

Страница 2: ...Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 Power Saving Mode Full Power Mode 14 2 Display lock 15 3 DMX 3 channel mode 15 4 DMX 7 channel mode 15 5 DMX...

Страница 3: ...udes Showtec Spectral M950 SW Blue White power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration o...

Страница 4: ...force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and a...

Страница 5: ...be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damag...

Страница 6: ...mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER...

Страница 7: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 8: ...x 8W 3 in 1 CW WW Amber LEDs Light output 35070 lumen 1 m Refresh rate 400Hz Control modes Built in programs Manual Master Slave DMX 512 Control protocol DMX 512 Dimmer 0 100 Strobe 0 20Hz Beam Angle...

Страница 9: ...plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servic...

Страница 10: ...Manual Mode Multiple Spectrals Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Spe...

Страница 11: ...ct the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains...

Страница 12: ...you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade...

Страница 13: ...should be 14 13 27 027 etc Please be sure that you do not have any overlapping channels in order to control each Spectral correctly If two or more Spectrals are addressed similarly they will work sim...

Страница 14: ...Ordercode 43630 Spectral M950 SW Menu Overview 13...

Страница 15: ...menu you can set the desired energy mode 01 Press the MODE button until the display shows or 02 When the display shows the device is operating in Power Saving Mode Its output is limited in response to...

Страница 16: ...e MODE button until the display shows 02 Press the UP DOWN buttons to set the desired DMX address The adjustment range is between 1 512 6 Color temperature With this menu you can set the desired color...

Страница 17: ...he MODE button until the display shows 02 Press the UP DOWN buttons to increase decrease the Amber LED brightness The adjustment range is between 0 255 from dark to brightest 03 You can combine Cool W...

Страница 18: ...htest 0 100 Channel 2 Cool White Dimmer must be open 0 255 Gradual adjustment Cool White from 0 100 Channel 3 Warm White Dimmer must be open 0 255 Gradual adjustment Warm White from 0 100 Channel 4 Am...

Страница 19: ...m 0 100 Channel 7 Amber Dimmer must be open and CH12 must be set between 0 35 0 255 Gradual adjustment Amber from 0 100 Channel 8 Fine Amber Dimmer must be open and CH12 must be set between 0 35 0 255...

Страница 20: ...clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly P...

Страница 21: ...y or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination pl...

Страница 22: ...tput 35070 lumen 1 m Color mixing CW WW A Beam angle 25 Dimmer 0 100 Strobe 0 20Hz Refresh rate 400Hz Housing Metal Flame retardant plastic DMX control via standard DMX controller On Board OLED displa...

Страница 23: ...Ordercode 43630 Spectral M950 SW Dimensions 22...

Страница 24: ...2015 Showtec...

Отзывы: