SHOWTEC 40637 Скачать руководство пользователя страница 7

 

  

 

 

   

 

Ordercode: 40637 

Flame Light 1,5m LED 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

 

 

Содержание 40637

Страница 1: ...Flame Light 1 5m LED V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40637 MANUAL ENGLISH...

Страница 2: ...lame Lights Master Slave Mode 8 Multiple Flame Lights DMX Control 9 Fixture Linking 10 Data Cabling 11 Control Mode 11 DMX Addressing 11 Main Menu Options 12 1 Stand alone Mode 12 1 1 Strobe Mode 12 1...

Страница 3: ...ame Light 1 5m LED DMX IEC power cable 1 10 m 2 silk flame imitations Velcro board User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that lea...

Страница 4: ...astened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a...

Страница 5: ...en light output and the illuminated surface must be bigger than 1 meter The maximum ambient temperature ta 40 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperat...

Страница 6: ...onnection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pi...

Страница 7: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 8: ...a DMX controller DMX modes 6 channels Flame length 1 2 m Total height 1 5 m Strobe 0 20Hz Strong metal housing Data Connector 3 pin XLR IN OUT Cooling Convection Fuse F2AL 250V Dimensions 520 x 250 x...

Страница 9: ...is not connected with a DMX cable it functions as a stand alone device 05 Please see pages 12 13 for more information about the Stand alone Mode One Flame Light Sound controlled 01 Fasten the effect l...

Страница 10: ...pply socket 04 Use a 3 p XLR cable to connect the Flame Light and other devices 05 Link the units as shown in Fig 03 Connect a DMX signal cable from the first unit s DMX out socket to the second unit...

Страница 11: ...equired by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To compl...

Страница 12: ...s respond to the DMX signal from the controller when you select the DMX address and save it the controller will display the saved DMX address the next time DMX Addressing The control panel equipped wi...

Страница 13: ...1 to decrease increase the strobe speed 1 2 Color Flow Mode 01 Set DIP switch 2 to ON position and all the remaining switches to OFF position in order to activate the Color Flow Mode 02 Turn the contr...

Страница 14: ...rder to obtain an unlimited range of colors 02 Turn the control 01 to decrease increase the color brightness 2 Sound controlled Mode 01 Set DIP switch 9 to ON position and all the remaining switches t...

Страница 15: ...otal sum 31 Explanation Since each unit has 6 channels each address advances by 6 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate...

Страница 16: ...15 Ordercode 40637 Flame Light 1 5m LED DMX Address Quick Reference Chart...

Страница 17: ...8 255 0 255 Gradual adjustment Green from 0 100 Channel 4 Blue CH1 must be set between 128 255 0 255 Gradual adjustment Blue from 0 100 Channel 5 Functions 0 10 Not functional 11 85 Strobe flash frequ...

Страница 18: ...nd audio connections with a damp cloth Make sure that connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate...

Страница 19: ...r not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug...

Страница 20: ...ignal pin OUT pin 1 earth pin 2 pin 3 Electro mechanical effects Control modes Stand alone Sound controlled Master Slave DMX 512 Sound control via built in microphone Strobe 0 20Hz Housing Strong meta...

Страница 21: ...20 Ordercode 40637 Flame Light 1 5m LED Dimensions...

Страница 22: ...21 Ordercode 40637 Flame Light 1 5m LED Notes...

Страница 23: ...22 Ordercode 40637 Flame Light 1 5m LED...

Страница 24: ...2015 Showtec...

Отзывы: