Ordercode: 40158 

XS-1 RGBW 

232-239 

Shutter open 

240-247 

Random shutters are on or off, from long to short intervals 

248-255 

Shutter open 

 

Channel 11 – Red 

0-255 

Red color intensity, from OFF to full ON 

 

Channel 12– Green 

0-255 

Green color intensity, from OFF to full ON 

 

Channel 13 – Blue 

0-255 

Blue color intensity, from OFF to full ON 

 

Channel 14 – White 

0-255 

White color intensity, from OFF to full ON 

 

Channel 15 – Color Programs 

0-7 

No Function 

8-127 

Static Colors, gradual change 

128-191 

Built-in Color Program 1 (color jump) 

192-255 

Built-in Color Program 2 (color fade) 

 

Channel 16 – Speed (CH15 must be set between 128-255 

0-255 

From slow to fast 

 

 

Maintenance 

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection:  
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and must 
not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Showtec XS-1 RGBW requires almost no maintenance. However, you should keep the unit clean.  
Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
The cooling-fans, color-wheel, the gobo wheel, the gobos and the internal lenses should be cleaned 
monthly, with a soft brush. 
Please clean internal components once a year with a light brush and vacuum cleaner.  
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 
 

 

Содержание 40159

Страница 1: ...XS 1 RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40159 MANUAL ENGLISH...

Страница 2: ...ol 9 Multiple XS 1 moving heads DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX Addressing 15 2 Channel...

Страница 3: ...decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the...

Страница 4: ...lation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure t...

Страница 5: ...own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always...

Страница 6: ...ct the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE...

Страница 7: ...r 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 8: ...onsumption 25W max at full output Beam Angle 3 Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol DMX512 9 or 16 DMX Channels Display 4 digits LED Optical system Dimmer...

Страница 9: ...not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subje...

Страница 10: ...ic If the device is set to sound control then the XS 1 RGBW will react to the music beats Please see page 15 for more information about the sound control options Multiple XS 1 moving heads Master Slav...

Страница 11: ...devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth uni...

Страница 12: ...ou must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade c...

Страница 13: ...e second XS 1 moving head should be 1 16 17 A017 the DMX address of the third XS 1 moving head should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to contr...

Страница 14: ...13 Ordercode 40158 XS 1 RGBW Menu Overview...

Страница 15: ...8 XS 1 RGBW Main Menu Options DMX address Channel Mode Master Slave Auto Sound controlled Sound Sensitivity Blackout LED Display Display Invert Pan Invert Tilt Invert Manual Mode Test Hours Used Firmw...

Страница 16: ...n buttons until the display shows 02 Press the ENTER button to open this menu 03 Use the UP DOWN buttons to toggle between the following Auto modes Master mode Normal slave mode Mirror slave mode 04 P...

Страница 17: ...shows 02 Press the ENTER button to open this menu 03 If the device has been set to ON the display is always ON 04 If the device has been set to OFF the display is OFF after 10 seconds 05 Press the SET...

Страница 18: ...s menu you can view how long your XS 1 has been used 01 Press the MENU button and then the Up Down buttons until the display shows 02 Press the ENTER button to open this menu 03 The XS 1 will now show...

Страница 19: ...rom slow to fast 132 139 Shutter open 140 181 Fast Close to slow Open from slow to fast 182 189 Shutter open 190 231 Slow Close to Fast Open slow Open from slow to fast 232 239 Shutter open 240 247 Ra...

Страница 20: ...acro 0 15 Not used 16 35 Color Macro 1 36 55 Color Macro 2 56 75 Color Macro 3 76 95 Color Macro 4 96 115 Color Macro 5 116 135 Color Macro 6 136 155 Color Macro 7 156 175 Color Macro 8 176 195 Color...

Страница 21: ...for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanicall...

Страница 22: ...nit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician Response Suspect three potential problem areas as the power supply...

Страница 23: ...ed with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and...

Страница 24: ...asy with only one bracket Strong narrow RGBW beam Compact housing Beam Angle 3 DMX control via standard DMX controller Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol...

Страница 25: ...24 Ordercode 40158 XS 1 RGBW Dimensions...

Страница 26: ...25 Ordercode 40158 XS 1 RGBW Notes...

Страница 27: ...26 Ordercode 40158 XS 1 RGBW...

Страница 28: ...2015 Showtec...

Отзывы: