SHOWTEC 40159 Скачать руководство пользователя страница 1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

XS-1 RGBW                           V1  

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Ordercode: 40159 

MANUAL 

ENGLISH 

Содержание 40159

Страница 1: ...XS 1 RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40159 MANUAL ENGLISH...

Страница 2: ...ol 9 Multiple XS 1 moving heads DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX Addressing 15 2 Channel...

Страница 3: ...decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the...

Страница 4: ...lation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure t...

Страница 5: ...own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always...

Страница 6: ...ct the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE...

Страница 7: ...r 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 8: ...onsumption 25W max at full output Beam Angle 3 Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol DMX512 9 or 16 DMX Channels Display 4 digits LED Optical system Dimmer...

Страница 9: ...not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subje...

Страница 10: ...ic If the device is set to sound control then the XS 1 RGBW will react to the music beats Please see page 15 for more information about the sound control options Multiple XS 1 moving heads Master Slav...

Страница 11: ...devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth uni...

Страница 12: ...ou must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade c...

Страница 13: ...e second XS 1 moving head should be 1 16 17 A017 the DMX address of the third XS 1 moving head should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to contr...

Страница 14: ...13 Ordercode 40158 XS 1 RGBW Menu Overview...

Страница 15: ...8 XS 1 RGBW Main Menu Options DMX address Channel Mode Master Slave Auto Sound controlled Sound Sensitivity Blackout LED Display Display Invert Pan Invert Tilt Invert Manual Mode Test Hours Used Firmw...

Страница 16: ...n buttons until the display shows 02 Press the ENTER button to open this menu 03 Use the UP DOWN buttons to toggle between the following Auto modes Master mode Normal slave mode Mirror slave mode 04 P...

Страница 17: ...shows 02 Press the ENTER button to open this menu 03 If the device has been set to ON the display is always ON 04 If the device has been set to OFF the display is OFF after 10 seconds 05 Press the SET...

Страница 18: ...s menu you can view how long your XS 1 has been used 01 Press the MENU button and then the Up Down buttons until the display shows 02 Press the ENTER button to open this menu 03 The XS 1 will now show...

Страница 19: ...rom slow to fast 132 139 Shutter open 140 181 Fast Close to slow Open from slow to fast 182 189 Shutter open 190 231 Slow Close to Fast Open slow Open from slow to fast 232 239 Shutter open 240 247 Ra...

Страница 20: ...acro 0 15 Not used 16 35 Color Macro 1 36 55 Color Macro 2 56 75 Color Macro 3 76 95 Color Macro 4 96 115 Color Macro 5 116 135 Color Macro 6 136 155 Color Macro 7 156 175 Color Macro 8 176 195 Color...

Страница 21: ...for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanicall...

Страница 22: ...nit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician Response Suspect three potential problem areas as the power supply...

Страница 23: ...ed with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and...

Страница 24: ...asy with only one bracket Strong narrow RGBW beam Compact housing Beam Angle 3 DMX control via standard DMX controller Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol...

Страница 25: ...24 Ordercode 40158 XS 1 RGBW Dimensions...

Страница 26: ...25 Ordercode 40158 XS 1 RGBW Notes...

Страница 27: ...26 Ordercode 40158 XS 1 RGBW...

Страница 28: ...2015 Showtec...

Отзывы: