55
Order code: 40102
Polar 300 Hybrid IP65 Moving Head
Problem
Probable cause(s)
Solution
One or more fixtures
do not function at all
No power to the fixture
●
Check if power is switched on and
cables are plugged in
Primary fuse blown
●
Replace fuse
Fixtures reset
correctly, but all
respond erratically or
not at all to the
controller
The controller is not connected
●
Connect controller
5-pin DMX OUT of the controller
does not match DMX IN of the first
fixture on the link (i.e. signal is
reversed)
●
Install a phase reversing cable
between the controller and the first
fixture on the link
Fixtures reset
correctly, but some
respond erratically or
not at all to the
controller
Poor data quality
●
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link
Bad data link connection
●
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables
Data link not terminated with 120
Ohm termination plug
●
Insert termination plug in output jack of
the last fixture on the link
Incorrect addressing of the fixtures
●
Check address settings
One of the fixtures is defective and
disturbs data transmission on the
link
●
Bypass one fixture at a time until
normal operation is regained: unplug
both connectors and connect them
directly together
●
Have the defective fixture serviced by
a qualified technician
5-pin DMX OUT on the fixtures does
not match (pins 2 and 3 reversed)
●
Install a phase-reversing cable
between the fixtures or swap pin 2 and
3 in the fixture, that behaves erratically
No light or LEDs cut
out intermittently
Fixture is too hot
●
Allow fixture to cool
●
Clean the fan
●
Make sure air vents are not blocked
●
Turn up the air conditioning
LEDs damaged
●
Disconnect fixture and return to your
dealer
The power supply settings do not
match local AC voltage and
frequency
●
Disconnect fixture. Check settings and
correct if necessary
Содержание 40102
Страница 21: ...20 Order code 40102 Polar 300 Hybrid IP65 Moving Head Menu Overview...
Страница 22: ...21 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Страница 23: ...22 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Страница 24: ...23 Order code 40102 Polar 300 Hybrid IP65 Moving Head...
Страница 58: ...57 Order code 40102 Polar 300 Hybrid IP65 Moving Head Dimensions...
Страница 59: ...58 Order code 40102 Polar 300 Hybrid IP65 Moving Head Notes...
Страница 60: ...2019 Showtec...