background image

 

 

 

5 

 

  

 

 

PSA-16A3C 

Product code: 50660 

2.

 

Safety 

 

Important 
Read and follow the instructions in this user manual before installing, operating or 
servicing this product. 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual. 

 

Warnings and Safety Instructions 

 

DANGER 
Electric shock caused by dangerous voltage inside
 

 

Do not open the device or remove any covers. 

 

Do not operate the device if the covers or the housing are open. Before operation, check if the 
housing is firmly closed and all screws are tightly fastened. 

 

Disconnect the device from electrical power supply before service and maintenance. 

 

DANGER 
Electric shock caused by short-circuit
 

This device falls under IEC protection class I. 

 

Make sure that the device is electrically connected to ground (earth). Connect the device only to a 
socket-outlet with ground (earth) connection. 

 

Make sure that the power source is equipped with a residual-current device. 

 

Do not cover the ground (earth) connection. 

 

Do not bypass the thermostatic switch or fuses. 

 

Do not let the power cable come into contact with other cables. Handle the power cable and all 
connections with the mains with caution. 

 

Do not modify, bend, mechanically strain, put pressure on, pull or heat up the power cable. 

 

Make sure that the power cable is not crimped or damaged. Examine the power cable periodically 
for any defects. 

 

Do not immerse the device in water or other liquids. Do not install the device in a location where 
flooding may occur. 

 

 

Attention 
Power supply 

 

Before connecting the device to the power supply, make sure that the current, voltage and 
frequency match the input voltage, current and frequency specified on the information label on the 
device. 

 

Make sure that the cross-sectional area of the extension cords and power cables is sufficient for the 
required power consumption of the device. 

 

 

Содержание PSA-16A3C

Страница 1: ...PSA 16A3C Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 50660 USER MANUAL ENGLISH V2...

Страница 2: ...e Non observance of the instructions in this user manual may result in serious injuries and damage of property 2021 Showgear All rights reserved No part of this document may be copied published or oth...

Страница 3: ...pecifications 9 Dimensions 9 4 Installation 10 Safety Instructions for Installation 10 Installation Site Requirements 10 Rack Mounting 10 Connecting to Power Supply 11 Schematic Overview 11 5 Setup an...

Страница 4: ...a 3 phase power distribution unit in theaters entertainment facilities public venues and similar It is suitable only for indoor use This device is not suitable for households and residential buildings...

Страница 5: ...ration and use of the product Important Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Informatio...

Страница 6: ...nly to a socket outlet with ground earth connection Make sure that the power source is equipped with a residual current device Do not cover the ground earth connection Do not bypass the thermostatic s...

Страница 7: ...enues and similar Any incorrect use may lead to hazardous situations and result in injuries and material damage This device is not suitable for households and residential buildings This device does no...

Страница 8: ...rson or are supervised by a skilled person for specific tasks and work activities associated with the installation service and maintenance of this product so that they can identify risks and take prec...

Страница 9: ...e maximum allowed current load is 16 A per phase The maximum allowed current load per output is 16 A Front View Fig 02 5 pin CEE power IN 3 pin CEE L1 OUT L1 Main Circuit Breaker MCB L2 Main Circuit B...

Страница 10: ...puts Outputs Power connector IN 1 x CEE male 16 A 3P N PE 400 V AC 50 60 Hz Power connector OUT 7 x CEE female 16 A 1P N PE 230 V AC 50 60 Hz Physical Dimensions 482 x 211 x 88 mm LxWxH 19 x 2 U LxH W...

Страница 11: ...ch rack The maximum ambient temperature ta 35 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 35 C Rack Mounting The device can be mounted in a standar...

Страница 12: ...I Make sure that the device is always electrically connected to the ground earth Before connecting the device to the socket outlet Make sure that the power supply matches the input voltage specified o...

Страница 13: ...ned for use in environment B Any other use not mentioned under intended use is regarded as non intended and incorrect use Attention Power supply Before connecting the device to the power supply make s...

Страница 14: ...tal current load of the connected devices Check if the external devices connected to the outputs are not damaged Move the main circuit breakers to ON position 7 Maintenance Safety Instructions for Mai...

Страница 15: ...7 2 1 Basic Cleaning Instructions on page 13 Store the device in the original packaging if possible 9 Disposal Correct disposal of this product Waste Electrical and Electronic Equipment This symbol on...

Страница 16: ...2021 Showgear...

Отзывы: