5
It is important that the door is kept square within the frame to allow the door to open freely.
When setting up the closing tension of the glass door on to the vertical seal, adjust the door by loosening the top and bottom
hinge adjustment screws. Then move the pivot block left or right to create a pressure on the vertical frame seal (see illustrations
above).
Make certain that the seal has contact with the full edge of the glass.
When tension has been set as desired, re-tighten the screws.
Orientate the pivot block screw cover caps (
A
) and push-fit on to the pivot blocks top and bottom.
Issue 1 - 07/11
Remove packing blocks shown in step . Measure between the frame and the pivot block, then with the drip deflector (Z5) cut a
short piece from it, to the same length as that measured. Fit this short piece between the frame and the pivot block with the drip
deflector to the outside of the enclosure as illustrated above.
Now measure between the frame and the pivot block on the longer side. Using the remainder of the seal (Z5) cut a length to that
just measured. Fit to the bottom of the door and ensure the lip of the drip deflecter is to the outside of the enclosure as illustrated
above.
STEP 8
Drip
deflector
(
Z5
)
Bottom
of door
Outside
enclosure
STEP 9
Bottom of door
(
A
)
Drip deflector
lip
Main Seal
Flipper.
Dry/outside
enclosure.
Wet/inside enclosure.
Correct set-up for handle side of pivot door.
Glass.