Show MPA-120 SERIES Скачать руководство пользователя страница 4

PUBLIC ADDRESS

AMPLIFIER

Servicing

Refer all servicing to qualified personnel. To
reduce the risk of electric shock, do not
perform any servicing other than that
contained in the operating instructions unless
you are qualified to do so .

Servicing is required when the apparatus has
been damaged in any way , such as power
supply cord or plug is damaged , liquid has
been spilled or objects have fallen into the
apparatus, the apparatus has been exposed
to rain or moisture , does not operate
normally, or has been dropped.

To reduce the risk of fire or electric shock,
do not expose this apparatus to rain or
moisture.

Do not use this apparatus near water.
Install in accordance with the manufacture-r's
instructions. Do not install near any heat
sources such as radiators, heat registers,
stoves, or other apparatus (including am-
plifiers) that produce heat. Do not block
any ventilation openings.

IMPORTANT SAFETY INSTRUCTIONS

Read these instructions.

Keep these instructions.

Heed all warnings.

Only use attachments/accessories spec-

ified by the manufacturer.

Power Cord and Plug

Do not defeat the safety purpose of the
polarized or grounding type plug.

A polarized plug has two blades with
one wider than the other. A grounding
type plug has two blades and a third
grounding prong. The wide blade or the
third prong are provided for your safety.
If the provided plug does not fit into your
outlet, consult an electrician for replace-
ment of the obsolete outlet.

Protect the power cord from being walk-
ed on or pinched particularly at plugs,
convenience receptacles, and the point

where they exit from the apparatus.

Cleaning

When the apparatus needs a cleaning, you
can blow off dust from the apparatus with

Follow all instructions.

No naked flame sources, such as lighted
candles, should be placed on the apparatus.

a blower or clean with rag etc.

Don't use solvents such as benzol, alcohol,
or other fluids with very strong volatility and
flammability for cleaning the apparatus body.
Clean only with dry cloth.

9

The mains plug is used as the disconnect device,
the disconnect device shall remain readily
operable.

AC:120W/ 240W; DC:88W/165W

AC 230V:285W/600W ;DC 24V: 161W/312W

80Hz-16kHz( 3dB)

Mic : -52dBV balanced

Phantom : -52dBV / 24V balanced

Line : -10dBV unbalanced

TEL IN : -10dBV balanced

Aux : -6dBV unbalanced

AMP IN : 0dBV unbalanced;

420

260

88mm(MPA series)

10.2kgs(MPA-120 series);

11.0kgs(MPA-240 series)

11.8kgs(PA-120 series);

12.8kgs(PA-240 series)

420

330

88mm(PA series)

MP3 PLAYER

CD-201

MON/TEL

ECHO

MP3 RECORDING

1%

MIC:

65dB

Phantom:

65dB

Line:

75dB

AUX:

80dB

COM , 4

, 25V ,70V , 100V

Z1

Z4 : 100V

4 Zone out volume controls;5 Zone out selector switch(units with"S")

3 REC selector switch(models of recording functions)

4 Input volume controls; 1 Aux volume controls

2 Treble/Bass controls; 1 Master volume control

RMS output

Frequency response

Input/Sensitivity

T.H.D.

S/N Ratio

Output

Controls

Zone out

BGM module

Dimensions(WxDxH)

Weight

Power consumption

TECHNICAL SPECIFICATIONS

Содержание MPA-120 SERIES

Страница 1: ...User s Manual MPA 120 240 SERIES PA 120 240 SERIES PUBLIC ADDRESS AMPLIFIER NF03329 2 0...

Страница 2: ...ad this manual carefully before operating this unit for the first time IMPORTANT TABLEOFCONTENTS INTRODUCTION CONTROL ELEMENT BACK GROUND MUSIC MODULE DESCRIPTION CONNECTION DESCRIPTION BLOCK DIAGRAM...

Страница 3: ...ly is connected The cover should be removed by the qualified personnel only No user serviceable parts inside Fuse To prevent a fire make sure to use fuses with specified standard current voltage type...

Страница 4: ...outlet consult an electrician for replace ment of the obsolete outlet Protect the power cord from being walk ed on or pinched particularly at plugs convenience receptacles and the point where they ex...

Страница 5: ...MIC XLR inputs MIC LINE PHANTOM exchange SW 1 AUX RCA INPUT 2 2 Tones BASS TREBLE 5 Input volume controls 1 MASTER 3 There are various modules like CD TURNER MP3 ECHO TEL for option 4 MP3 player and...

Страница 6: ...please see the BGM module description in detail Note MP3 player recording CD 201are assembled to different units of the series 7 1 Switch on the equipment and start the player by pressing the E key 2...

Страница 7: ...t terminals which are controlled by key 9 19 MUSIC ON HOLD VOL It is used to monitor volume of black ground music and AUX 24 LINE OUT It is connected to recorder and pass on mixed signal 25 AUX IN It...

Страница 8: ...SD USB h REC In the status of play or pause the model plays next song or previous one when press or and the status has no change It plays the next file or previous file when hold or for about 2 secon...

Отзывы: