Ordercode: 41520  

Infinity iW-715 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

FASE

 

BLUE 

BLACK 

SILVER 

NULL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

 
 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 

regardless of the agreement of which the obligation is resulting. 
 

 

 

Содержание indiniti iw-715

Страница 1: ...Infinity iW 715 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 41520 MANUAL ENGLISH...

Страница 2: ...grams 9 Multiple Infinity s Master Slave control 9 Multiple Infinity s DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu O...

Страница 3: ...s exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced I...

Страница 4: ...not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure...

Страница 5: ...nger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yoursel...

Страница 6: ...5 Ordercode 41520 Infinity iW 715 Mounting a clamp to the underside of the Infinity moving head Improper installation can cause serious damage to people and property...

Страница 7: ...ys a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief des...

Страница 8: ...andard DMX controller User selectable Pan Tilt ranges 540 360 180 Reverse Pan Tilt movement Special Pan Tilt movement blackout Pan 0 540 Tilt 0 270 Pan Tilt resolution 16 bit Control DMX 512 Master Sl...

Страница 9: ...1 Lens with variable beam angle 02 Menu Buttons LCD Display Backside 03 DMX signal connector IN 3 pin 04 DMX signal connector OUT 3 pin 05 Earth connection 06 Fuse F4AL 250V 07 Neutrik Powercon OUT 08...

Страница 10: ...ays use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 When the Infinity is not connected by a DMX cable it functio...

Страница 11: ...ices 05 Link the units as shown in figure 4 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units...

Страница 12: ...DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Infinity s on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data ca...

Страница 13: ...hould be 1 001 the DMX address of the second Infinity should be 1 14 15 015 the DMX address of the third Infinity should be 15 14 29 029 etc Please be sure that you don t have any overlapping channels...

Страница 14: ...13 Ordercode 41520 Infinity iW 715 Menu Overview...

Страница 15: ...dress Setting Left Infinity Logo Right 1 DMX Addressing With this menu you can set the DMX address 01 Press the button and select 02 Press the button to confirm You can choose 512 different DMX addres...

Страница 16: ...o change the value from No to YES 04 Once you have selected the desired setting press the button to store your settings 05 If the device has been set to master all slave devices will follow the master...

Страница 17: ...set 4 colors Red 000 255 Green 000 255 Blue 000 255 White 000 255 07 If you press the OK button at the Reset function a new Menu will open 08 You can set 2 different reset options Pan Tilt Reset All...

Страница 18: ...ed the desired mode press the buttons to change the value from 000 to 255 04 If you press the OK button at the Manual Test a new Menu will open 05 You can set 7 different Test options 06 Once you have...

Страница 19: ...3 Pan fine 16 bit Channel 4 Tilt fine 16 bit Channel 5 PAN TILT Speed 0 255 From Max Speed 0 to Min Speed 255 Channel 6 Red Dimmer intensity CH11 and CH12 must be open 0 255 Red from 0 100 Channel 7 G...

Страница 20: ...slow on and fast off from fast to slow 105 109 Shutter open 110 124 Strobe effect 4 random strobe from fast to slow 125 129 Shutter open 130 144 Strobe effect 5 random strobe fast on and slow off from...

Страница 21: ...eed 130 134 Fan Temperature controlled 135 139 Dimming Fast 140 144 Dimming Smooth 145 239 No Function 240 247 XY Smoothing model open 248 255 XY Smoothing model to shut down Channel 14 Built in Progr...

Страница 22: ...opped at any position you wish Channel 3 PAN TILT Speed 0 255 From Max Speed 0 to Min Speed 255 Channel 4 Built in Colors Dimmer and Shutter must be open 0 4 No Function 5 9 Color 1 10 14 Color 2 15 1...

Страница 23: ...145 149 Shutter open 150 164 Strobe effect 6 random strobe slow on and fast off from fast to slow 165 169 Shutter open 170 184 Strobe effect 7 pulse strobe from fast to slow 185 189 Shutter open 190 2...

Страница 24: ...year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are to be inspected by a skilled person once a year The following point...

Страница 25: ...e electric power source 02 Remove the 6 screws on the front side of the Infinity 03 Gently pull the front cover from the device 04 Disconnect the plug from the PCB 05 Remove the 2 screws holding the b...

Страница 26: ...e Replace the fuse See page 23 for replacing the fuse 05 If all of the above appears to be O K plug the unit in again 06 If you are unable to determine the cause of the problem do not open the Infinit...

Страница 27: ...nk not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is...

Страница 28: ...Color balance Separate RGBW adjustment On Board 16x2 Character display DMX control via standard DMX controller User selectable Pan Tilt ranges 540 360 180 Reverse Pan Tilt movement Special Pan Tilt mo...

Страница 29: ...28 Ordercode 41520 Infinity iW 715 Notes...

Страница 30: ...29 Ordercode 41520 Infinity iW 715...

Страница 31: ...30 Ordercode 41520 Infinity iW 715...

Страница 32: ...2014 Showtec...

Отзывы: