Troubleshooting
Symptom
Corrective Steps
The POE
does not
power up
1. Verify that a reliable power cord
is used.
2. Verify that the voltage at the
power inlet is between 100 and 240
VAC.
3. Remove and re-apply power to
the device and check the indicators
during power up sequence.
The PD
does not
operate
1. Verify that the SHOREPHONE
POE detects a PD.
2. Verify that the PD is designed for
PoE operation.
3. Verify that you are using a
standard Category 5/5e/6, straight-
wired cable, with four pairs.
4. If an external power splitter is in
use, replace it with a known-good
splitter.
5. Ensure input Ethernet cable is
connected to the DATA IN port.
6. Verify that the PD is connected
to the Data & Power port.
7. Try to reconnect the same PD
into a different SHOREPHONE
POE. If it works, there is probably a
faulty port or RJ45 connection.
8. Verify that there is no short over
any of the twisted pair cables or
over the RJ45 connectors.
The end
device
operates,
but there
is no data
link
1. Verify that the port indicator on
the front panel is continuously lit.
2. If an external power splitter is in
use, replace it with a known-good
splitter.
3. Verify that for this link, you are
using standard UTP/FTP Category 5
straight (non-crossover) cabling,
with all four pairs.
4. Verify that the Ethernet cable
length is less than 100 meters from
the Ethernet source to the
load/remote terminal.
5. Try to reconnect the same PD
into a different SHOREPHONE
POE. If it works, there is probably a
faulty port or RJ45 connection.
Port Connectivity
Indication
Ethernet
Cat
.
5
Cable
Terminal
Figure 1: Connecting the SHOREPHONE POE
Indicators
Port LED
Indicated Behavior
Yellow On
Power is on (power is active)
Green On
A remote terminal is connected
Green Blinking
Overload state or short-circuit
Specifications
Environmental Specifications
Mode
Temperature
Humidity
Operating
0 to 40°C
32 to 104°F
10 to 90%; (no
condensation
allowed)
Storage
-20 to 70°C
-4 to 158°F
10 to 90%; (no
condensation
allowed)
Electrical Specifications
Input Voltage
100-240 VAC (50/60 Hz)
Maximal Input Current
0.5 Ampere
Available Output Power
(max.)
16.8 Watts
Nominal Output Voltage
48VDC
Ethernet Interface
Input (DATA IN)
: Ethernet
10/100/1000Base-T
RJ45 female socket
Output (DATA & POWER
OUT)
: Ethernet
10/100/1000Base-T, plus
48VDC
RJ45 female socket, with
DC voltage on wire pairs,
4 - 5 (+) & 7 - 8 (-).
Functions and Features
The SHOREPHONE POE is a Single Port Midspan that offers a
compact and cost effective power solution for IP phones, WLAN
access points, network cameras and other IP terminal
installations.
The SHOREPHONE POE converts AC power to 48VDC power is
then provided over the Ethernet cable.
The SHOREPHONE POE supports up to
10/100/1000Mbps pass through data rates.
The SHOREPHONE POE can be powered via universal
AC input and can provide up to 20W.
SHOREPHONE POE EMC Compliance
:
♦
FCC Part 15 class B and EN55022 class B
♦
EN55024
♦
VCCI
SHOREPHONE POE Safety Compliance:
♦
UL/cUL per 60950-1
♦
GS mark
Preliminary Steps
♦
Ensure that AC power is applied to the SHOREPHONE
POE, using an operational AC cable with an appropriate
ground connection.
♦
Ensure that output Ethernet cable is connected to the
DATA & POWER OUT port.
♦
Verify that power ready Ethernet compatible device is
connected.
WARNING
Do not use cross over cable between the SHOREPHONE
POE output port and the load device
Installation
The SHOREPHONE POE can be placed on a desktop.
:
Before placing the SHOREPHONE POE:
♦
Do not to cover SHOREPHONE POE or block the airflow to
the PoE with any foreign objects. Keep the SHOREPHONE
POE away from excessive heat and humidity and free from
vibration and dust.
♦
Ensure that the cable length from Ethernet network source
to the terminal does not exceed 100 meters (330 feet). The
PoE is not a repeater and does not amplify the Ethernet
data signal.
♦
Use a splitter if desired; ensure that the splitter is connected
close to the terminal and not on the SHOREPHONE POE!
♦
No “on-off” switch exists; simply plug the SHOREPHONE
POE into an AC power source.
Installing the Unit
Refer to Figure 1.
1. Connect the SHOREPHONE POE to an AC outlet (100 -
240VAC), using a standard power cord.
2. Connect the DATA IN jack (input) to the remote Ethernet
network switch's Patch panel and the DATA & POWER OUT jack
(output) to the terminal.