background image

Operation Manual Shodex RSpak KC-811 and KC-811 6E  

Version 2020 

 

 

 
 
 

Operation Manual 

Shodex™ 

RS

pak™ 

KC-811 and KC-811 6E 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Europe, Middle East, Africa, Russia 
www.shodex.de 

Sales Office: 
Showa Denko Europe GmbH 
Shodex Business 
Konrad-Zuse-Platz 3 
81829 Munich 
Germany 
 

Technical Support: 

[email protected] 
+49 (0)89 / 93 99 62 37 
 

Quotes and Orders: 

[email protected] 
+49 (0)89 / 93 99 62 34 

Содержание RSpak KC-811

Страница 1: ... Shodex RSpak KC 811 and KC 811 6E Europe Middle East Africa Russia www shodex de Sales Office Showa Denko Europe GmbH Shodex Business Konrad Zuse Platz 3 81829 Munich Germany Technical Support info shodex de 49 0 89 93 99 62 37 Quotes and Orders order shodex de 49 0 89 93 99 62 34 ...

Страница 2: ...oblems related to losing your health or leaking Attention Use the column within the regular range of flow rate pressure and temperature There is a danger of deteriorating the performance when it is handled beyond the permissible range even for a short time See the Section 4 Usable Conditions for the permissible ranges 3 Specifications Product code Product name Functional group Size mm Particle siz...

Страница 3: ... amount up to 20 to the mobile phase to reduce the absorptivity 6 Mounting and Start up 1 Before mounting the column on the liquid chromatograph replace the solvent in the chromatograph with the mobile phase Caution In replacing a water insoluble organic solvent in the chromatograph replace it first with a water soluble organic solvent such as acetone or ethanol and then replace the water soluble ...

Страница 4: ...ounting and Storage 1 Set the flow rate at 0 2 mL min turn off the heater and let the column stand as is until it cools down to room temperature 2 Stop the pump and dismount the column 3 Cap both ends of the column put it back in the same case in which it was delivered from the manufacturer and store the case in a place where the temperature does not fluctuate more than 5 C Caution i Do not remove...

Страница 5: ...not remove the end fittings of the column under any circumstances 2 Do not make a strong impact on the column such as hitting or dropping on the floor 3 Replace the solvent in the LC system with the eluent to be used before connecting the column 4 Connect the column so that the flow direction corresponds to the arrow mark on the tag 5 When the column is not used for a month or more replace the in ...

Страница 6: ...of the following cases 3 1 If the Shodex Column is not used in accordance with the operating manual 3 2 If the Shodex Column is remodelled by anyone other than person or firm designated by Showa Denko K K 3 3 If the Shodex Column is disposed of 3 4 If the Shodex Column is resold by the user without giving prior written notice to Showa Denko K K 3 5 If the performance of the Shodex Column is not co...