Shodex IC YS-50 Скачать руководство пользователя страница 6

ver.211201E

 

SHOWA DENKO K.K. (https://www.shodex.com/)

 

11. Warranty (Ver. 4COLUMN) 

 

(1) Showa Denko K. K. warrants that the Shodex

 product, at the time of delivery to the user, will conform to 

the specification of the attached CERTIFICATE OF ANALYSIS, if the Shodex product is used in accordance 
with the attached operating manual. The foregoing warranty is exclusive and is in lieu of all other warranties 
with respect to the Shodex product, whether written, oral, implied, statutory or otherwise. No warranties by 
Showa Denko K. K. are implied or otherwise created, including, but not limited to, the warranty of merchantability 
and fitness for particular purposes.   

 

(2) Any claim of inconformity to the specification must be notified to Showa Denko K.K. within ten (10) days after 
delivery to the user. User’s exclusive remedy and Showa Denko K.K.‘s exclusive liability for such claim are 
limited to the replacement of the Shodex product in question. In no event is Showa Denko K.K. liable for any 
indirect, incidental or consequential damage arising out of in connection with the Shodex product, whether or 
not such damage is allegedly based on breach of warranty, negligence or otherwise.   

 

(3) No warranty is made in any of the following cases:   
3-1 If the Shodex product is not used in accordance with the operating manual   
3-2 If the Shodex product is remodeled by anyone other than person or firm designated by Showa Denko K.K.   
3-3 If the Shodex product is disposed of   
3-4 If the Shodex product is resold by the user without giving prior written notice to Showa Denko K.K.   
3-5 If the performance of the Shodex product is not conform to the specification of the attached CERTIFICATE 

OF ANALYSIS due to any of the reasons below:   

a. Computer virus   
b. Impurities contained in the sample, reagent, gas air or cooling water provided by the user   
c. Breakdown or malfunction of equipment, apparatus or component used in combination with the Shodex   

product  

d. Force majeure such as fire, earthquake, flood, other natural disaster, crime, riot, act of terrorism, war or 

radioactive contamination   

 

(4) In no event is Showa Denko K.K. liable for   
4-1 the results of analysis or preparations using the Shodex product or any portion of the same, including, but 

not limited to, the reliability, accuracy, efficacy and safety of said results, and   

4-2 the occupational hazard in the use of the Shodex product, whether or not such use is made in accordance 

with the attached Conditions for use.   

 

(5) The Shodex product is for laboratory use only. It must not be used for clinical diagnosis. Showa Denko K.K. 
is not liable for any use of the Shodex product except laboratory use. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Following names are trademarks or registered trademarks of SHOWA DENKO K.K. 
Shodex, AFpak, Asahipak, AXpak, CLNpak, CXpak, HILICpak, MSpak, ODP, OHpak,   
ORpak, RSpak, SUGAR, USPpak. 

 

Products described in the operation manual are not intended for medical use or medical applications.

 

Содержание IC YS-50

Страница 1: ...ackage and outside of the column for any damage 2 Please check if product name and serial number written on the column package column name tag and enclosed Certificate of Analysis CoA are matching and correct 1 Introduction Thank you for purchasing the Shodex product Shodex IC YS 50 is an ion chromatography column suitable for a simultaneous analysis of monovalent and divalent cations It is applic...

Страница 2: ...d use ultra pure water freshly generated by a water purification system or water from a newly opened HPLC grade distilled water bottle Use HPLC grade acetonitrile whenever possible acetonitrile left in an opened bottle for a long time should not be used The content may have been changed absorbed moisture or has been contaminated Always use freshly prepared solvents Solvents stored for a long time ...

Страница 3: ...e pump was stopped while the eluent inside the column was still hot as the eluent temperature decreases its volume also decreases This may result in creating an empty space in the column and deteriorates the column Note It is recommended to set the pump limiter to avoid exceeding the maximum pressure 7 3 Solvent Exchange When replacing the solvent start the system at less than 0 5 mL min Recommend...

Страница 4: ... Storage Remove the column from the system after replacing the in column solvent with the shipping solvent Securely tighten the end caps and store the column at a location with stable temperature a cool and dark space is recommended Refer to section 7 3 Solvent Exchange for how to replace the eluent Attention Never allow inside of the column to dry It can damage the column 9 Column Inspection Insp...

Страница 5: ...ct on the column Do not drop or hit the column on a hard surface Refer to the Shodex website https www shodex com for product details and their applications For additional assistance contact the distributor from whom you purchased the column or contact your regional Shodex support office https www shodex com en support_office list ...

Страница 6: ...anyone other than person or firm designated by Showa Denko K K 3 3 If the Shodex product is disposed of 3 4 If the Shodex product is resold by the user without giving prior written notice to Showa Denko K K 3 5 If the performance of the Shodex product is not conform to the specification of the attached CERTIFICATE OF ANALYSIS due to any of the reasons below a Computer virus b Impurities contained ...

Отзывы: