background image

LOG SET PLACEMENT IN FIREPLACE

XXXX

XXXX

XXXX

XX

Glowing Embers

 to the

area marked with 

“XXX” (see Figure 6

).

Do not apply 

Glowing Embers

 to the main burner.

Figure 6- Glowing Ember Placement

INSTALLATION 

(Continued)

DECORATIVE CRUSHED SHALE

Included with this Gas Log Set is a bag of Crushed 

This Shale is provided to enhance the look and feel 

of your log set and fireplace. Its only function is to 

be decorative. Simply spread the Crushed Shale on 

your fireplace floor around the bottom of your log 

set burner/grate to give the appearance of burnt 

ash. It can also be used to cover your gas supply    

Caution: Never place the shale, or any other object 

(not provided with your gas log set and instructed 

for that purpose) onto the burners of the unit. 

Be creative in the placement. You do not have to 

use all of the supplied shale.   

CRUSHED SHALE SHOWN 

AS PROVIDED

line coming from the wall to your burner.

Shale (

see Figure 7

)

Figure 7- Crushed Shale

11

OPTIONAL ON/OFF 

REMOTE CONTROL SET

INSTALLATION AND OPERATION

- + - +

COMMUNICATION BETWEEN THE

REMOTE CONTROL TRANSMITTER

AND THE RECEIVER

To program the transmitter to the receiver

,

move

the three positions slider of the receiver inthe

REMOTE

position and depress the

ON/OFF

key

of the transmitter. The System has an automatic

learning mode that allows the receiver to mate

with a new trans

-

mitter in the event the trans

mitter must be replaced. Assoon as the receiver

module receives the firstcorrectcommand from

any remote control it captures the new address

and then "beeps"3 times to confirm the syncron-

ization and command execution..

Remote control set NOT included with log set. If 

using the optional remote control set, follow these 

additional instructions. 

Install four

(

4) "AA"

batteries into the

remote receiver box

as shown on the left.

Install three

(

3) "AAA"

batteries into the

remotecontrol

as shown on the left.

Be sure to place the remotereceiver in a cool loc-

ation in the fireplace. Do not place the reciever

in a location directly in front of the burner system.

Содержание GRVFE24LMV

Страница 1: ...ER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This app liance is not convertible for use with other gases Aftermarket Completion of sale not f...

Страница 2: ...replace screen is in place before funning this app liance Unless other provisions are made for comb ustion air the screens shall have an opening or openings for introduction of combustion air into the fireplace If this appliance is installed in a fireplace that has glass doors the doors must be left open when the appliance is in use WARNING This product can expose you to chemicals including lead a...

Страница 3: ... system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages 17 through 20 11 Do not run appliance where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this appliance to cook food or burn paper or other objects 13 Never place any ob...

Страница 4: ...s no matches batteries or other sources to light heater PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code and Ventilation All spaces in homes fall into one of the following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space Theinformationonpages4through6willhelpyouclassify your space and provide adequate ventilation WARNING This heater s...

Страница 5: ...outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Figure 1 Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 2 VentilationAir from Outdoors DETERMINING FRESH AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confin...

Страница 6: ...may be operated does not meet the required volume for indoor combustion air combustion and ventilation air shall be provided by one of the methods described intheNationalFuelGasCode ANSIZ223 1 NFPA 54 the International Fuel Gas Code or applicable local codes CONTINUED VENTED OPERATION Area of Various Standard Round Flues Diameter ins Area sq ins 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq...

Страница 7: ...inyl or cloth wall cover ingsoroperatingappliancewhereimpurities suchastobaccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing appliance in rooms without enough ventilation air may cause mildew to form CHECK GAS TYPE Use the correct gas type natural gas or pro...

Страница 8: ...uce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas pressure heater regulator damage could occur Install the external regulator with the vent pointing down as shown in Figure 4 Pointing the vent down protects it from freezing rain or sleet INSTALLATION CLEARANCES WARNING Maintaintheminimumclear ances Mantel Clearances for Install...

Страница 9: ...at you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into appliance gas controls If sediment trap is not installed or is instal...

Страница 10: ...rosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once CONTINUED 10 WALL MOUNTED SWITCH INSTALLER SUPPLIED INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER FAMILIAR WITH LOW VOLTAGE WIRING PROCEDURES WARNING Do not connect this switch or log set to any electrical source Electrical shock and or fire hazard will occur Connecting to Log Set 1 Remove Jumper...

Страница 11: ...e Figure 7 Figure 7 Crushed Shale 11 OPTIONAL ON OFF REMOTE CONTROL SET INSTALLATION AND OPERATION COMMUNICATION BETWEEN THE REMOTE CONTROL TRANSMITTER AND THE RECEIVER To program the transmitter to the receiver move the three positions slider of the receiver inthe REMOTE position and depress the ON OFF key of the transmitter The System has an automatic learning mode that allows the receiver to ma...

Страница 12: ... midway back on grate Log 4 in notches at left Log 5 in notches at right Place log 1 at back Log 6 crossing Log 4 at the top left to Log 1 Center in fireplace Log 3 at front of grate Place Logs 7 and 8 on the Log 1 Log 4 Log 3 Log 2 Log 5 Log 6 Log 7 Log 8 1 2 3 4 5 6 7 8 ...

Страница 13: ...S WARNING If operate this heater with glass doors closed If you operateheaterwith doorsclosed heat buildup inside fireplace willcauseglasstoburst Make suretherearenoobstructions across openings of fireplace You must operate this heater with sure fireplace screen is closed before running heater NOTICE Duringinitialoperationof new heater burning logs will give off a paper burning smell Orange flame wil...

Страница 14: ...ton This will light pilot The pilot is attached Note If pilot does not light no spark contact a qual ified service person or gas supplier for repairs Until re with match see Manual Lighting Procedure page 15 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas...

Страница 15: ... Replace or remove low batteries as soon as possible to prevent corrosion damage to remote control acces sory 15 HAND HELD TRANSMITTER OPERATION Move the side Slide Switch into the ON position tow ards the flat end of the unit Press and hold the control button see Figure 11 on the Hand Held Remote until burner turns on Press and hold the control button again until the burner turns off Figure 11 ON...

Страница 16: ...nd let cool Remove blockage Blocked burner flame holes will create soot MAIN BURNER BURNER FLAME PATTERN Figure 15 shows the correct burner flame patern Figure 16 shows the incorrect burner flame patern turn Gas Log Set off see Turning OFF the Ap pliance page 15 see Cleaning and Maintenance this page see Troubleshooting page 22 CLEANING AND MAINTENANCE WARNING Turn off Gas Logs and let CAUTION keep...

Страница 17: ... See Fig 18 See Fig 18 Figure 18 Pilot Inlet Air Hole 19 17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...Model Number GRVFE24 N L MV 1 2 3 4 9 10 11 11 L 14 7 O O 5 0 0 6 0 0 o 8 311 20 24 12 o 13 L 14 15 16 21 17 18 19 22 25 24 23 20 ...

Страница 21: ...120 EBTBR RMH 120 EBTBR Tray Bracket Right 1 1 Tray Bracket Left RMH 120 EBTBL RMH 120 EBTBL RMH 120 00260 RMH 120 00254 RMH 120 18318 RMH 120 08419 NG RMH 120 08421 P RMH 120 90434A SBNCJ00071A SH 111 RMH 120 00051 49738375 Orifice Holder EB Tee 375 Comp Tube 375 EB Elbow Piezo Igniter RMH 120 90945 RMH 120 90945 RMH 120 00546 RMH 120 CMPT RMH 120 CMPT RMH 120 1831805 RMH 120 1831805 Gas Control ...

Страница 22: ... low pilot will not stay lit heater will not produce the specified heat propane gas supply volume may be low You may feel your gas pressure is too low If so contact your local natural or propane gas supplier Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty TECHNICAL SERVICE You may have further questions about installation opera ti...

Страница 23: ...NOTES 23 ...

Страница 24: ...coloring of any kind use or installation contrary to specified instructions and applicable building codes including heating the product to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alteration misuse abuse hostile environments or improper installation repair...

Отзывы: