Inspection and cleaning of the flame monitor
Remove the burner cover and pull out the
flame monitor, and check whether or not
its lens is dirty/foul.
If the lens is dirty/foul, please wipe the
surface of the lens with a soft cloth, etc.
until it becomes clear.
Restore the flame monitor, fix burner cover
with screws
Inspection of "dirt/dusts" on main unit
Check whether or not dirt/dusts is on or
If dust is found, clean with a vacuum
around the heater.
cleaner or wipe with a soft cloth, etc.
Periodic Inspection
The heater must be checked, if used for a long time. Please ask your dealer to inspect the
heater every two (2) seasons.
How to connect the Control device
Uncouple the terminals (A) attached to the
tip of white wires that come out of the burner
base.
Connect both male and female terminals,
which are uncoupled, to the connecters
(B) of control device.
Observations - When removing the flame monitor, hold it by its main assembly; do not pull out the cord.
1
3
2
1
2
1
1
2
・
When the heater is controlled by anotherdevice
(such as a thermostat or a timer), the heater could
turn itself on at any time.
Observations
All manuals and user guides at all-guides.com
all-guides.com