6-1 Indoor control mode
(
AMS-07UR4SNVG4
(
VT
、
VL
、
VQ
、
UP
、
UL
、
UQ
、
NS
、
ZC
、
ZA
)
4
、
AMS-09UR4SNVG4
(
VT
、
VL
、
VQ
、
UP
、
UL
、
UQ
、
NS
、
ZC
、
ZA
)
4
、
AMS-12UR4SNVG4
(
VT
、
VL
、
VQ
、
UP
、
UL
、
UQ
、
NS
、
ZC
、
ZA
)
4
、
AMS-18UR4SVUP3
(
VG3
、
VL3
、
VT3
、
UP3
、
UL3
、
UQ3
)、
AMD-09
(
12/18
)
UX4SJD
、
AMC-12(18)UX4SAA
1.Major general technical parameters
1 Conditionings for operation: Ambient temperatures: (-15 - +45 ), relative humidity
℃
(45 - 85%).
2 Remote receiver distance: 8 m.
3 Remote receiver angle: Less than 80 degrees.
4 Temperature control accuracy: ±1 .
℃
5 Time error: Less than 1%.
6 The power supply for the air conditioner is a.c 220V
~
240V, 50Hz, with its fluctuation in
the range of (176V – 264 V).
2. Functions of the controller
. Control function
3.1Emergency switch
1. When the machine is turned OFF, by press and hold the emergency switch for 5
seconds, with 3 beeps , the indoor unit would turn to emergency run. In such station,
machine would be forced to turn to cooling operation with the indoor fan speed being set at
high speed, the flaps sweeping and the air conditioner’s operation is irrelevant with room
temperatures.
2. If a remote signal has been received during the emergency run, the machine will
operate upon the command of such a remote signal.
3.2 Operator-machine communication
The air conditioner has a thermal sensor to detect room temperatures. Some remote
controller is equipped with a thermal sensor (Such remote controller has the function of
man-machine communication. For details, refer to the section for the remote controller). In
addition, there is a thermal sensor at the indoor air inlet. In the case where the remote
controller is equipped with a thermal sensor, the default setting for room temperatures is
subject to the detection by the remote controller. The remote controller detects the room
temperature once every 20 seconds, and automatically transmits a signal at an interval of 3
minutes or when a change in the room temperature is detected. If the indoor control unit has
not received a remote signal for more than 10 minutes, the control function will be
automatically switched over to the thermal sensor on the indoor unit.
3.3 Timer function
1. Timer on: When set to start in a time by the remote controller, the air conditioner starts in
the timer on condition. When the set time is up, the air conditioner will turn on and operates
in the preset conditions after receiving a signal from the remote controller. If the air
conditioner has not received a signal from the remote controller when the set time is up, it
will automatically start and operate in the preset conditions.
2. Timer off: When set to stop in a set time by the remote controller, the air conditioner will
start in the timer off condition. When the set time is up, the air conditioner will turn off after
receiving a signal from the remote controller. If the air conditioner has not received a signal
from the remote controller when the set time is up, it will turn off automatically.
Содержание SRH-PM18DC
Страница 11: ...3 3 O OU UT TL LI IN NE ES S A AN ND D D DI IM ME EN NS SI IO O 14 3 2 OUTDOOR MODEL AMW2 16U4SGC1 ...
Страница 20: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 23 2 AMS 18UR4SVUP3 VG3 VL3 VT3 UP3 UL3 UQ3 ...
Страница 21: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 26 OUTDOOR 1 AMW2 16U4SGC1 ...
Страница 22: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 29 4 AMW3 24U4SZD ...
Страница 23: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 32 7 AMW4 36U4SAC ...
Страница 64: ...9 9 P PA AR RT TS S L LI IS ST T 67 MODEL AMS 18UR4SVUP3 UL3 UQ3 VG3 VL3 VT3 ...
Страница 67: ...9 9 P PA AR RT TS S L LI IS ST T 89 Mode AMW4 36U4SAC ...