background image

 

18

 

  

  GB-IE 

Drill the 

LH Roof Panel (A5615) 

as shown below. Place onto the left hand side of your building with the 

drill side facing in the middle. Place on the 

RH Roof Panel (A5615) 

and fix with 

60mm Screws (A0035) 

using the pilot holes drilled. Then drill and screw inline with the roof bearers so the panels are secure to 

the Pent Panels. Finally, fix with 

40mm Nails (A0025) 

on top, making sure the nails go into the walls. 

10 

LH Roof Panel 

(A5615)x01 

60mm Screws 

(A0035)x11

 

5mm  

RH Roof Panel 

(A5615)x01 

Back  

Back  

40mm Nails 

(A0025)x14 

Make sure to mark 

and cut slots into 

the partition wall 

so that the roof 

panel can sit flush. 

Содержание Aster 2020

Страница 1: ... 12x8 Aster 2020 Version 01 Sasha Leney 21 01 2020 These instructions are for your safety Please read through them thoroughly before use PLEASE KEEP THIS LEAFLET FOR FUTURE REFERENCE Mass 487 7 kg ...

Страница 2: ... Для получения копии инструкции или копия на другом языке пожалуйста отправьте по электронной почте или написать по указанному ниже адресу TR Başka bir dilde talimatları veya bir kopyasını bir kopyası için bir e posta gönderebilir veya aşağıdaki adrese yazınız EN For a copy of the instructions or a copy in another language please send an email or write to the address below I Per richiedere una cop...

Страница 3: ...embly Only use child and animal safe wood preservative Do not use creosote Allow the wood preservative to fully dry before use Regularly check the building for wear and tear Getting Started GB IE EVERY PRECAUTION IS TAKEN TO ENSURE THAT YOUR BUILDING HAS NO ELEMENT INCORRECTLY PLACED OR POSSIBLY HAZARDOUS HOWEVER PRIOR TO USE PLEASE CHECK ALL SURFACES FOR THE FOLLOWING 1 RAISED GRAIN SPLINTERS San...

Страница 4: ... immediately prior to assembly The building must have been re treated and re sealed annually NOTE Wood is a natural product and therefore the following are excluded from the warranty Colour change Warping Splitting Preparation of base We recommend that the base onto which your building will stand should be at least 75mm larger in each direction than the total floor size of the building Actual floo...

Страница 5: ... The 6 golden rules of maintenance 1 Timber widely recycled 2 Metal fixings widely recycled 3 Glass widely recycled 4 Roofing felt not currently recycled packaging Building 1 Ensure your base is level and firm 2 Ensure the building is not sitting directly on the ground using damp proof membrane or the optional timber base 3 Ensure every piece of timber and surface especially that is hidden upon as...

Страница 6: ...Stacked Parts List Description part No Qty 06 ...

Страница 7: ...Stacked Fascia and Nail Bag Parts List Description part No Qty 07 ...

Страница 8: ...In more detail GB IE 08 ...

Страница 9: ...In more detail GB IE 09 ...

Страница 10: ...d Nail A0035 x 54 60mm Posi Drive Screw Nail bag contents Building Photographs It will be greatly appreciated if you could forward images of your completed building to sales shiregb co uk Description part No Qty 16mm Panel pin A0024 x 108 13mm A0032 x 18 25mm Posi Drive Screw 10 ...

Страница 11: ...ge 4 You will need Hammer Spirit level Ladder 1mm 5mm drill bit Drill Tape measure Ruler Sand paper Gloves Saw Pencil Goggles A helper for some tasks Screwdriver Sharp knife Masking tape When you see the drill icon Only ever drill through the first piece of framework which will be a pilot hole for the screw to attach the second piece of framework The required drill bit size is shown with the icon ...

Страница 12: ...ill the Floor Panel A2162 as shown below Then fix the Shed Floor A2163 to it using 3x 60mm Screws A0035 using the pilot holes you just drilled Carefully turn over the floor and put it on your base 12 A2162 5mm If using a drill or electric screwdriver carefully but firmly push the opposite end to the screwdriver bit into the screw head and keep the pressure on to prevent the screwdriver spinning in...

Страница 13: ... Fit the Door Handles A2179 to the Single Door Panel A5606 and the Bi Fold Door Panel A5607 as shown below This should be repeated on both sides of the door The keys are EITHER screwed to the panel framework OR in the nail bag GB IE Door Handle A2179 x02 03 Verandah Floor A2164 x01 Joining Plate 62x15 A2182 x01 60mm Screws A0035 x02 25mm Screw A0032 x02 25mm Screw A0032 x16 Single Door Panel A5606...

Страница 14: ...ing Place the Plain Panel into the corner of the floor and push the Pent up to it and fix with 60mm Screws A0035 14 DO NOT FIX WALLS TO FLOOR UNTIL ASKED 04 The wall panels will have transport blocks on the bottom of the panels Gently knock them off with a hammer before assembly LH Plain Panel A2166 x01 5 mm RH Plain Pent A5602 x01 60mm Screws A0035 x03 Inline with floor bearer ...

Страница 15: ...e drilled at and angle 05 15 GB IE Drill the Single Door Panel A5606 so that the hole is inline with the floor bearers Fix with 60mm Screws A0035 using the pilot holes drill in the Pent Panel 06 5mm Inline with floor bearer RH Plain Panel A2166 x01 60mm Screws A0035 x02 5mm 60mm Screws A0035 x03 DO NOT FIX WALLS TO FLOOR UNTIL ASKED Inline with floor bearer Single Door Panel A5606 x01 ...

Страница 16: ...create the shed compartment making sure the framework is facing inwards 07 GB IE Drill the LH Window Pent A5603 as shown below Fix to the Plain Panel using 3x 60mm Screws A0035 08 5mm Partition Pent A5605 x01 60mm Screws A0035 x06 NOTE Some holes drilled for later use 5mm LH Window Pent A5603 x01 60mm Screws A0035 x03 ...

Страница 17: ...line with the floor bearers Then screw to your building using the pilot holes in the Door and Window Pent 09 5mm Bi Fold Door Panel A5607 x01 60mm Screws A0035 x05 Inline with floor bearer DO NOT FIX WALLS TO FLOOR UNTIL ASKED NOTE Some holes drilled for later use MAKE SURE LINES UP WITH FRAMEWORK ON PARTITION PANEL ...

Страница 18: ... using the pilot holes drilled Then drill and screw inline with the roof bearers so the panels are secure to the Pent Panels Finally fix with 40mm Nails A0025 on top making sure the nails go into the walls 10 LH Roof Panel A5615 x01 60mm Screws A0035 x11 5mm RH Roof Panel A5615 x01 Back Back 40mm Nails A0025 x14 Make sure to mark and cut slots into the partition wall so that the roof panel can sit...

Страница 19: ...12x56x2383 A5617 to the front of your building as shown below 12 GB IE Make sure your building is square and true Fix the walls into the floor with 60mm Screws A0035 using the pilot holes drilled previously 11 60mm Screws A0035 x16 19 Coverstrip 12x56x2130 A2180 x03 Coverstrip 12x56x2320 A5616 x01 Coverstrip 12x56x2383 A5617 x02 40mm Nails A0025 x18 A2180 A2180 A2180 A5616 A5617 A5617 ...

Страница 20: ...have been supplied Fit the first piece of felt so that there is an even overhang front and back Pull tight and secure with 13mm Felt Nails A0023 approximately 100mm apart Repeat with the middle strip of felt as below 13 20 3 8M Felt Strip A2175 x02 Tidying the corner ...

Страница 21: ...e building using 4x40mm Nails A0025 in each Fix the two Fascia 19x95x1879 A2176 to the front of your building as below Finally fit the Final 95x19 A2178 to the front of your building centrally and secure with 2x40mm Nails A0025 15 13mm 13mm Felt Nails A0023 x50 3 8M Felt Strip A2175 x01 Tidying the corner Fascia 12x95x1879 A2176 x02 40mm Nails A0025 x18 Final 95x19 A2178 x01 Fascia 19x95x2591 A561...

Страница 22: ...crylic A2192 within the frames Then fit the 1636 Beading A2193 and 321 Beading A2194 with 6x16mm Panel Pins A0024 per long side and 3 per short side GB IE WEAR CORRECT SAFETY EQUIPMENT 22 16 322x1632 Acrylic A2192 x06 GB IE 1636 Beading A2193 x12 321 Beading A2194 x12 16mm Panel Pins A0024 x108 ...

Отзывы: