Shinybow USA SB-5688LCM-CT Скачать руководство пользователя страница 2

SAFETY INFORMATION

 

THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL

1.

Save the carton and packing material even if the equipment has 

  

arrived in good condition. Should you ever need to ship the unit, use only the original

 factory packing.

2.

Read all documentation before operating your equipment. Retain all documentation for future reference.

3.

Follow all instructions printed on unit chassis for proper operation.

4.

Do not spill water or other liquids into or on the unit, or operate 

 

the unit while standing in liquid.

5.

Make sure power outlets conform to the power requirements listed on the back of the unit.

6.

Do not use the unit if the electrical power cord is frayed or broken. The power supply cords should be routed so that they are not likely to be walked on

 or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit

7.

Always operate the unit with the AC ground wire connected to the electrical system ground. Precautions should be taken so that the means of grounding of

 a piece of equipment is not defeated.

8.

Mains voltage must be correct and the same as that printed on the rear of the unit. Damage caused by connection to improper AC voltage is not covered by 

 any warranty.

9.

Power down & disconnect unit from mains voltage before making connections.

10.

Never hold a power switch in the 

ON

 position.

11.

Do not use the unit near stoves, heat registers, radiators, or other heat Producing devices.

12.

Do not block fan intake or exhaust ports. Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit,  

13.

 

 

 

 

such as a bed, rug, carpet, or completely enclosed rack. If the unit is used in an extremely dusty or smoky environment, the unit should be 

 
 
 

Periodically 

blown free

 of foreign matter.

14.

 

Do not remove the cover. Removing the cover will expose you to potentially dangerous voltages. There are no user serviceable parts inside.

15.

Do not drive the inputs with a signal level greater than that required 

 

to drive equipment to full output.

16.

Non-use periods. The power cord of equipment should be unplugged from the outlet when left unused for a long period of time.

Service Information Equipment should be serviced by qualifier service personnel when:

A.

The power supply cord or the plug has been damaged.

B.

Objects have fallen, or liquid has been spilled into the equipment.

C.     The equipment has been exposed to rain

D.     The equipment does not appear to operate normally, or exhibits a marked change in performance

E.     The equipment has been dropped, or the enclosure damaged.

 from the appliance. 

IMPORTANT SAFETY INSTRUCTIONS

To insure the best from this product, please read this manual carefully. Keep it in a safe place for future reference.

To reduce the risk of electric shock, do not remove the cover from the unit. No user serviceable parts inside. Refer servicing to qualified personnel. 

To reduce the risk of fire, do not expose the unit to rain, water or excessive moisture.

Do not force switched or external connections.

When moving the unit disconnect the serial port connections first then the power cable and finally the interconnecting cables to other devices.

Do not attempt to clean the unit with chemical solvents or aerosol cleaners, as this may damage the unit. Use a clean dry cloth.

Installation of this unit should be in a cool dry place, away from sources of excessive heat, vibration, dust, moisture and cold.

This symbol is intended to alert the user to the presence of uninsulated 

 

 

 

 

 

enclosure tha may be of sufficientmagnitude to constitue a risk of  
electric shock to persons.

This symbol is intended to alert the user to the presence of important
operational and maintenance (serving) instructions in the literature
accompanying the appliance.

T   prevent  electric shock do not use this (polarised) plug with an   

o

extension cord, receptacle or other outlet unless the blades can 
be fully inserted to prevent blade exposure.  
T  prevent electric shock, match wide blade of plug to wide slot, 

o

 fully insert.

Caution:

CAUTION

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK),

NO USER SERVICEABLE PARTS INSIDE,

REFER SERVICING TO QUALIFIED SERVICE PERSONAL.

WARNING!

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK

 

T

 

 

 

 

I

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

 

.

DO NOT OPEN

 

 

of uninsulated “dangerous voltage” within the products enclosure that 

RISK OF ELECTRIC SHOCK

Содержание SB-5688LCM-CT

Страница 1: ...r You will find this unit easy to install and highly reliable but it is essential that you read this manual throughly before attempting to use 8x8 HDMI CAT6 Matrix switcher HDMI CAT6 MATRIX SWITCHER S...

Страница 2: ...ut 16 Non use periods The power cord of equipment should be unplugged from the outlet when left unused for a long period of time Service Information Equipment should be serviced by qualifier service p...

Страница 3: ...______________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______...

Страница 4: ...g HDBaseT specifications Supporting HDMI Video with embedded audio RS 232 IR bi directional and all over a single CAT5e 6 7 cable With a signal bandwidth of 340Mhz there is no signal degradation High...

Страница 5: ...ol via RS232 port Front Panel push button IR wireless remote control Third party RS232 controller via simple ASCII 11 Support world wide control functions ALL OFF RECALL ENTER MEMORY EDID LOCK 12 Supp...

Страница 6: ...meters maximum HDMI I O Connector HDMI Type A SMD 19pin Female Type Dimensions LxWxH 19 x 9 85 x 3 50 482mmx250mmx88mm Rack Mount 2RU High 19 Rack Mount 2U 440L with rack mount Power Supply AC 100 23...

Страница 7: ...nations Example Press Destination 1 3 5 then press Source 2 will route Input 2 to Output 1 3 5 respectfully OUTPUT STATUS DISPLAY 3 Each Output destination Channel shows which input source is assigned...

Страница 8: ...5 6 7 8 8x8 HDMI CAT6 MATRIX SWITCHER ALL OFF RECALL MEMORY EDID ENTER LOCK 1 2 3 5 6 7 8 SOURCE DESTINATION SOURCE DESTINATION 4 1 2 3 5 6 7 8 4 IR OUTPUT 1 2 3 4 5 6 7 8 INPUT 8 6 7 5 4 3 2 1 8 FUNC...

Страница 9: ...ru 8 or Destination keys 1 thru 8 as the memory preset location press RECALL button press 1 thru 4 on either Source or Destination row press ENTER The pre set configuration will execute Operation comp...

Страница 10: ...nnector HDMI Female connector Connect a signal link of HDMI direct digital video audio to this Female HDMI connector This connector supports HDMI digital video audio and DVI digital video sources Note...

Страница 11: ...8 IR SIGNAL TO ROOM Support eight of IR Extender to control signal to eight rooms Extend cable distance maximum 300Meters 1000 feet When you plug the CAT5e 6 7 IR extender into the external port the r...

Страница 12: ...Status Step 3 Press the ENTER button To set EDID mode The switcher will return to operation mode Select Embedded EDID Mode 1 FSS Mode 2 H24 3D Mode 3 H24 3D M Mode 4 H36 3D Mode 5 H36 3D M Mode 6 128...

Страница 13: ...the EDID data from a destination It will save that EDID information into EPROM and the EDID data cannot change Please select new learning destination to sources or change to one of the embedded EDID m...

Страница 14: ...7 1920x1200 60Hz DVI D DVI Support DVI D 1920 x 1200 60Hz Mode 1 FSS Fast Speed Start Automatic capture most suitable EDID from Destination to Source Mode 2 H24 3D 1080p 24 bits Audio Support PCM 2CH...

Страница 15: ...All Sources The button will flash blue and the display will show the current Embedded EDID Status Learning EDID Single to ALL Step 1 Press destination button 1 thru 8 Learning anyone 1 8 Destination E...

Страница 16: ...r multiple sources Destination device 1 2 3 will be set to the highest common resolution and Audio available and source device 1 will output this same resolution 6 6 Auto mode definition Common Resolu...

Страница 17: ...AT6 IR in IR To projector 4 IR Extender Transmitter SB 101 Use SB 101 IR Transmitter to Extend IR signal to Projector 5 IR Extender Receiver SB 100 Use SB 100 IR Receiver to receive the Projector IR R...

Страница 18: ...ination RS232 Control Via SB 5688CT TX RS232 in 3 IR Extender Transmitter SB 101 Use SB 101 IR Transmitter to Extend IR signal Sample connection using IR Transmitters SB 101 with SB 5688CT and SB 6335...

Страница 19: ...6 7 OUTPUT RS232 TX RX HDMI 1 INPUT 1 CAT5e 6 7 OUTPUT RS232 TX RX HDMI RS 232 RoHS 95 EC RoHS 8 POWER AC100V AC240V 50 60Hz IR From ROOM 7 6 5 4 3 2 1 ALL out 8 IR To ROOM 7 6 5 4 3 2 1 ALL in SW IR...

Страница 20: ...l input 1 8 select buttons The supplied IR remote control Or through the RS 232 serial communications port Powered down PAGE 20 SB 5688 INSTRUCTION OPERATION MANUAL POWER 1 2 3 4 5 6 7 8 ON OFF MEMORY...

Страница 21: ...9F6 09F6 09F6 09F6 09F6 09F6 09F6 09F6 10EF 20DF 30CF 40BF 50AF 609F 708F 807F 09F6 09F6 09F6 09F6 09F6 09F6 09F6 09F6 For example Select Destination 1 to show Source 1 8 The IR Data Code list Destina...

Страница 22: ...4CB 35CA 36C9 37C8 38C7 09F6 09F6 09F6 09F6 09F6 09F6 09F6 09F6 IR 04 DATA CODE SOURCE 1 SOURCE 2 SOURCE 3 SOURCE 4 SOURCE 5 SOURCE 6 SOURCE 7 SOURCE 8 41BE 42BD 43BC 44BB 45BA 46B9 47B8 48B7 09F6 09F...

Страница 23: ...09F6 09F6 09F6 09F6 09F6 09F6 09F6 09F6 IR 07 DATA CODE SOURCE 1 SOURCE 2 SOURCE 3 SOURCE 4 SOURCE 5 SOURCE 6 SOURCE 7 SOURCE 8 718E 728D 738C 748B 758A 7689 7788 7887 09F6 09F6 09F6 09F6 09F6 09F6 09...

Страница 24: ...on The pre set configuration will execute To Enable CEC CONSUMER ELECTRONIC CONTROL CEC Press EDID button Press OFF button Press EDID button The pre set configuration will execute To Disable CEC PAGE...

Страница 25: ...3 4 4 4 HDMI MATRIX SW SW 5645p ON OFF INPUT 2 INPUT 3 INPUT 4 When you plug the External IR extender into the switcher the front panel IR receiver remains active PAGE 25 SB 5688 INSTRUCTION OPERATIO...

Страница 26: ...CE CONNECT a PC or CONTROL SYSTEM VERSION COMPATIBLE V2 0 1 RS 232 SERIAL INTERFACE Pin RS 232 Definition 1 Not used 2 TX Transmitter 3 RX Receiver 4 Not used 5 GND Ground 6 Not used 7 Not used 8 Not...

Страница 27: ...returned REGULATORY COMPLIANCE The product complies with the relevant standards for CE FCC and RoHS approval The power Adaptor Supply has been tested for compliance with UL CSA and CE standards TROUBL...

Страница 28: ...1399 Wildfire Lane Frisco TX 75034 1 877 SHINY USA 1 877 744 6987 1 972 377 2508 sales shinybowusa com MULTIMEDIA AUDIO AND VISUAL www shinybowusa com...

Отзывы: