Connection example of CMC-001-2
(Fig. 4-2)
Connection example of CMC-001-3
(Fig. 4-3)
Connection example of CMC-001-4
(Fig. 4-4)
(3) Confirm the COM port number.
1
Right-click "Start" - Click "Device Manager" from menu.
2
Click
[Ports (COM & LPT)].
If
[USB Serial Port (COM3)]
appears, COM port has been allotted No.3.
(e.g.)
(Fig. 4-5)
3
Close the
[Device Manager]
displays.
(4) Turn the power supply to the instrument ON
.
(5) Confirm communication between PC and the instrument
.
Simplified versions of communication software and various monitoring software
are available. Monitoring software can be downloaded from our website.
(https://shinko-technos.co.jp/e/)
Select the COM port number confirmed at step (3), and start communication.
5. Specifications
Rating
USB I/F standard
Corresponds to USB Specification 2.0.
DTE (PC side) speed
9600 bps [For instruments with Serial communication
(C5 option), 9600/19200/38400 bps, Selectable]
Connector spec
PC side: USB plug (Type A)
Instrument side: RS-485 (Y-type terminal, Ferrules,
Modular connector)
Operating Environment
Operating system
Windows 7/8/10 (Japanese/English)
Personal computer
OS certified PC (Intel Pentium processor or compatible
microprocessor), USB port
General Structure
Case (Material, Color) ABS, Black
Cable (Length, Color) 3 m (can be extended by 1 m fixed length units), Black
Other
Power source
Bus power (Supplied from PC via USB.)
Supply voltage
5 V DC
Current consumption 150 mA Max.
Ambient temperature 0 to 50 (32 to 122 ) (No icing)
Ambient humidity
35 to 85 %RH (Non-condensing)
Weight
Approx. 130
g
Environmental spec
Conforms to RoHS directive.
Accessories
Instruction manual: 1 copy
SHINKO TECHNOS CO., LTD.
OVERSEAS DIVISION
Head Office: 2-5-1, Senbahigashi, Minoo, Osaka, 562-0035, Japan
URL:
https://shinko-technos.co.jp/e/
TEL: +81-72-727-6100
E-mail:
FAX: +81-72-727-7006
Host computer
USB port
USB communication cable
CMC-001-2 (Sold separately)
+
-
C
A
B
Screw Type Plug for Lines
(Terminal block ATB-001-1)
(Sold separately)
COM
YA(-)
YB(+)
NCL-13A (Max. 31 units)
Host computer
USB port
USB communication cable
CMC-001-3 (Sold separately)
Bottom of the DCL-33A
Communication cable CDD
DCL-33A (Max. 31 units)
Host computer
USB port
Communication
expansion module
QMC1
Control module
QTC1-40
USB communication cable
CMC-001-4 (Sold separately)