46(62)
System can
’
t
operate
1. Main power switch disconnected
1. Turn off main power switch
2. Timer switch at ON state
2.Reset timer power-off button and re-start
3. Motor overload or power phase
reverse
3. Check if circulation, regeneration motor
and power supply works normally.
Material shortage
for a long time,
suction blower
doesn
’
t work
1. Main power switch disconnected or
at ON position
1. Close main power switch
2.Hopper photosensor, microswitch
poor contact
2. Adjust or replace
3. Signal cable break
3. Re-connect or replace
Motor doesn
’
t run
1. Thermo-relay trips
1. Check the reason and reset
2. Contactor doesn
’
t match.
2. Check whether it is burnt.
3. Power default phase or motor burnt 3. Check or replace
Material is full but
suction blower
continuous
1. Photosensor or micro-switch is
connected through
1. Check or replace
2. Signal cable short circuit
2. Check signal cable
3. Contactor failure or contact
conglutinated
3. Check or replace
4. PLC error
4. Check or replace
After several
loading, the
hopper is still not
full
1. Material is used up
1. Fill the material
2. Air pipe leakage
2. Check or replace
3. Filter blocked
3. Clean
4. Diaphragm valve or shut-off valve
closed
4. Check if the air pressure of diaphragm
valve and shut-off valve is enough, and
solenoid valve is burnt, circuit
connection is well connected or not.
5. Motor blade error
5. Check and repair
E-13Low
temperature
alarm
1. Pipe heater fault
1. Check and replace
2. Parameter setting error
2. Adjust F-40 and F
-
41 setting value
E-12 Heater
1. Lack of power or failure
1. Check and replace
2. Parameter setting error
2. Adjust F-42 setting value
Содержание SCD-160Ux2/200H