![Shini CD SERIES Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/shini/cd-series/cd-series_manual_1258051040.webp)
40(44)
4.3 Adjustment of Air Rate
Adjustment of air rate is the most important factor for the drying result, should
adjust the air outlet and inlet when drying different material.
For example:
1) When heat and brake the electronic, galvanized and baked-finish products,
the air-inlet and air-outlet should be closed completely.
2) When dry up the plastic materials and other products contained much
moisture, the air-inlet and air-outlet should be opened properly.
Picture 4-2
:
Adjustment of Air Rate
4.4 Start-up Timer Setting
Turn on timer switch after all switch has been on, take down the glassy shield
outside of the timer, then push the small black switch to "Auto". Set current time
and drying time required, cover the glassy shield. Therefore the cabinet dryer
will run automatically till drying time.
Picture 4-3
:
Start-up Timer Setting
Output setting
Open setting: Reverse the setting section of dial entad, at this time, red mark
appears in the dial.(shown in the above picture)
Содержание CD SERIES
Страница 1: ...CD Series Cabinet Dryer Date Apr 2016 Version Ver B English...
Страница 2: ......
Страница 6: ...6 44...
Страница 11: ...11 44 1 3 2 Outline Drawing Picture 1 1 Outline Drawing...
Страница 20: ...20 44 2 4 Electrical Diagram 2 4 1 Parameter 400V...
Страница 21: ...21 44 2 4 2 Main Circuit 400V Picture 2 4 Main Circuit 400V...
Страница 22: ...22 44 2 4 3 Control Circuit 400V Picture 2 5 Control Circuit 400V...
Страница 23: ...23 44 2 4 4 Components Layout 400V Picture 2 6 Components Layout 400V...
Страница 24: ...24 44 2 4 5 Electrical Components List 400V Table 2 3 Electrical Components List CD 5 400V...
Страница 25: ...25 44 Table 2 4 Electrical Components List CD 9 400V...
Страница 26: ...26 44 Table 2 5 Electrical Components List CD 20T 400V...
Страница 27: ...27 44 Table 2 6 Electrical Components List CD 20L 400V...
Страница 28: ...28 44 2 4 6 Parameter 230V...
Страница 29: ...29 44 2 4 7 Main Circuit 230V Picture 2 7 Main Circuit 230V...
Страница 30: ...30 44 2 4 8 Control Circuit 230V Picture 2 8 Control Circuit 230V...
Страница 31: ...31 44 2 4 9 Components Layout 230V Picture 2 9 Components Layout 230V...
Страница 32: ...32 44 2 4 10 Electrical Components List 230V Table 2 7 Electrical Components List CD 5 230V...
Страница 33: ...33 44 Table 2 8 Electrical Components List CD 9 230V...
Страница 34: ...34 44 Table 2 9 Electrical Components List CD 20 230V...
Страница 35: ...35 44 Table 2 10 Electrical Components List CD 20L 230V...
Страница 43: ...43 44 6 Maintenance and Repair Clear off the dust on the motor fan periodically avoid the damage to the blower...