![ShinewayTech PPM-50 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/shinewaytech/ppm-50/ppm-50_user-manual_1257998019.webp)
PPM-50 PON Power Meter User’s Manual
Shineway Technologies, Inc.
- 13 -
Get from input power
Set Reference
Set 1310nm: -10.00 dBm
Set 1490nm: -10.00 dBm
Set 1550nm: -10.00 dBm
Meas&Save
Reference
Save Option
2011-09-15 17:41
5
Reference ON-OFF
OFF
>
Fig 3.14
In Figure 3.14, press
and
to select item: “Reference On-Off” and “Set
Reference”.
[Reference On-Off]: press
to select ON or OF. If reference is On, then the
power value result will be the different value with the showed reference value.
[Set Reference]: Enable select result value as reference value; or press
,
,
,
to select reference value.
3.4 Measurement and Save
Press
and
to [Meas&Save] interface, see Figure3.15
Reference
Meas&Save
Save Option
1310nm
-20. 00
1490nm
-13. 00
1550nm
-8. 00
dBm
FAIL
dBm
WRNG
dBm
PASS
ONU
OLT
VIDEO
OLT_name_XXXXXX
ONT_name_XXXXXX
2011-09-15 17:41
5
>
<
Fig 3.15
In Figure 3.15, PPM-50 will shows the tested power value by corresponding working
wavelength; meanwhile, if threshold function is ON, PPM-50 will shows the compared
value with threshold value, the “test record indicator” will be On.
Under [Meas&Save] interface, press
to save current record.
Note: After set the file name in [Save Option] interface, the saved file name will be
auto-sequence when saving record.