background image

- English -

3

English

1. UNPACKING AND ASSEMBLY

While unpacking and assembling

Check whether the correct number of components has been
supplied as in figure 1.

Check that the apparatus is complete, undamaged and
correctly assembled

Any damaged or defective parts must be replaced before use.

The package must include:
1.

The SparX Single Air helmet

2.

The respirator protection system (turbo unit +  waist
belt)

3.

Lithium-ion battery

4.

The tube, its anti-fire cloth and both end fittings

5.

The shoulder harness

6.

The air flow tester

7.

The lithium-ion battery charger

8.

The carrying bag

If any of the above components are not included in your kit,
please contact the supplier immediately.

2. FILTER REPLACEMENT

The pre-filter and filter expected lifetime is 12 months. When
under intensive use, check the filter cleanliness periodically
and if needed, change them more often than every 12
months.

Содержание SPARX SINGLE

Страница 1: ...SPARX SINGLE AIR INSTRUCTION MANUAL...

Страница 2: ...ion is given If you are not sure about the concentration of pollution or about equipment performance ask the industrial safety engineer Warnings The respirator system devices should be used by well tr...

Страница 3: ...2 The respirator protection system turbo unit filter waist belt 3 Lithium ion battery 4 The tube its anti fire cloth and both end fittings 5 The shoulder harness 6 The air flow tester 7 The lithium io...

Страница 4: ...device was stored for more than 15 days When the battery is new or has been stored for more than 3 months charge it and discharge it at least twice in a row to reach the nominal rated charge capacity...

Страница 5: ...system must be stored in a dry clean area in the temperature range of 10 C to 55 C and relative humidity less than 90 RH If the equipment is stored at temperature below 0 C the battery must be allowed...

Страница 6: ...English 6 English 9 INSTALLING ON THE BELT Make sure the belt is securely fastened...

Страница 7: ...airflow must be tested before using If the marble can t reach the minimum flow level do not use the system Change the filter or the battery and retest the air flow MUST TEST AIR FLOW ALARM TEST If th...

Страница 8: ...has ecessive current Check and remove physical failure and restart hte system Return to dealer if LCD still shows E02 Low battery Change the battery Filter blocked Tube blocked Remove obstruction and...

Страница 9: ...n Air Flow Rate and Filter Load LCD Display Air flow level and data Battery capacity Filter status Belt Size 35 2 5 x 51 2 5 in 900mm x 1300mm 14 MARKING EXPLANATION Powered filtering device EN 12941...

Страница 10: ...13 02 111 Airduct with headgear 4 13 02 411 Inner visor clear lens 5 13 01 043 Lock sliders 6 13 03 101 Filter cover 7 13 03 104 Spark Arrestor 8 13 03 103 Pre filter 9 13 03 102 P3 level filter 10 13...

Отзывы: