
OPERATION
DH235
22
X7702241803
© 12/19 ECHO Incorporated
1.
Stop Switch
Move stop switch (A) away from
the STOP position.
2.
Purge Bulb
Pump purge bulb (C) until fuel is
visible and flows freely in the clear
fuel tank return line. Pump bulb an
additional 4 or 5 times.
3.
Recoil Starter
Place the unit on a flat, clear area.
Grip the support handle securely
with one hand, and pull the recoil
starter handle (D) until engine
starts.
Note: If engine does not start
after 5 pulls, use Cold Start
Procedure.
Stopping Engine
1.
Throttle
Release throttle trigger (F) and
allow engine to return to idle
before shutting off engine.
A
C
B
C
D
F