External Trigger Mode
External trigger mode will allow the flash rate of the ST-329BL 
stroboscope to be controlled by an external signal, such that the 
flash rate will automatically increase or decrease when the signal 
is altered, so that it may remain in unison with the speed of a 
changing target.

Connector of External Input/Output
Charging round socket:
 positive 16V, negative 16V 
External synchronous USB port: 1.+12V output 2.OUT exter-

nal pulse input 3.-12V output

External Pulse Input: 3 Pin M-12 connection. The input signal 

will have the following characteristics.

Input Frequency: 60-12,000 fpm Input pulse width:
over 50 µs. Delay angle: 0-359° (every 1°) Delay time: 0-999 ms
(every 1ms)

Additionally, there are several settings that can be adjusted in Ex-
ternal Trigger mode, including phase shift, delay time, and flash 
duration. 

The flash timing can be set by using the positive or negative edge 
of an external trigger signal. Also the delay of the flash timing can 
be set by time in (msec) or degrees (°).

Press “mode” once and the unit enters EXTER 1. In this mode, 
speed (FPM) automatically flash according to the external trigger 
signal.

After setting the parameters, generally the detected object has an 
advanced or lag phenomenon. To adjust, press the “+” or “-” for 
fine-tuning, change the perimeter parameters, so that detected 
object achieves a still image. In this setting process, the unit will 
automatically save the last setting.

External Trigger Mode: LCD Display Information
The frequency of the external signal is measured each period, 
while the latest external frequency measurement is updated ev-
ery 50 ms.

External Trigger Flash Delay Setting
A flash angle delay can be programmed into the ST-329BL to de-
lay the flash after an external trigger signal is detected. The unit of 
delay can be set to time (msec) or degree (°). Use “+” or “-”key to 
alternate between the settings of delay angle or delay time.

Delay Time Setting
The delay time can be set to incorporate a delay from the external 
pulse input to the flash output. The delay can be set from 0-999 
ms with a resolution of 1 ms.

Note: Because of the existence of a delay in internal calculation, 
the ST-329BL flashes 60 µs after the external signal input. This 
results in the actual setting delay time having approxi60 
µs added to the delay.

Example
Trigger: positive edge 

Delay Time: 10 ms

The ST-329BL does not flash at the 1st trigger pulse as shown 
below in the diagram, ST-329BL flashes from the external trigger 
after 10 ms.

4

+

_

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание ST-329BL

Страница 1: ...ATIONS Flash Rate Range 60 to 120 000 FPM Accuracy 0 01 1 digit of F S 77 F 25 C Lamp Lifetime Approximately 3 5 years depending on usage Display Backlit LCD Resolution 60 12 000 FPM 0 1 FPM 12 001 120 000 FPM 1 FPM Flash Duration 0 1 2 5 Phase Shift 0 359 Power Requirement 100 120 VAC Optional 220 260 VAC upon request Input Signal 12 V Pulse Input M 12 3 Pin Input Signal Range 60 120 000 FPM Inpu...

Страница 2: ... adjustments rotate the dial quickly The flash rate range and resolution will be different according to the selected measur ing range One function of a stroboscope is to provide a stopped image of a rotating target when the flash rate of the stroboscope has matched the rotational speed of the target object The strobo scope will show a single image when the flash rate is set to a lesser multiple of...

Страница 3: ...ET key then enter this mode When the rotation speed of the target object and the flash rate of the ST 329BL becomes equal the phase shift function can be used to delay the flash so that the image will appear to rotate incrementally The phase shift angle can be increased or decreased 3 each time the or keys are pressed or the adjustment dial is turned CW or CCW The sub display will show the cumulat...

Страница 4: ...ed object has an advanced or lag phenomenon To adjust press the or for fine tuning change the perimeter parameters so that detected object achieves a still image In this setting process the unit will automatically save the last setting External Trigger Mode LCD Display Information The frequency of the external signal is measured each period while the latest external frequency measurement is update...

Страница 5: ...59 Delay angle decreases as the dial is rotated to the left The set tings will eventually go to 0 as the angle decreases past 359 Parameter Settings To enter parameter setting menu press MODE until the LCD dis plays P When the display shows P press the SET key to cycle between the various parameter settings available range trigger edge delay time LCD backlight Auto Shut off Initial To store the se...

Страница 6: ...If the backlight is set to on as a power saving feature it can be adjusted to automatically shut off from 1 to 1000 seconds if no keypad or dial operation has occurred The LCD backlight will turn back on with keypad or dial oper ation Factory Reset Initial To reset unit to factory values choose Yes under Initial in the parameter setting mode Then press SET Model Length LED Groups LED s ST 329BL 0 ...

Отзывы: